BioMatrix Technology
Embrace human nature
Patients have unique, individual characteristics – biovariabilities. Different physiologies and anatomies – but also the way we interact with them and technology – cause unwarranted variations in imaging results. BioMatrix Technology helps to overcome these challenges by automatically adjusting to patient biovariability. By embracing human nature in this way, we can personalize examinations and help expand precision medicine.
BioMatrix highlights
MAGNETOM Sola
Experience how MAGNETOM Sola embraces human nature at 1.5T – expanding precision medicine.
Faster workflow
Transform care delivery in MRI: Schedule one more patient per hour with AI powered BioMatrix and GO technologies.
Towards precision medicine
Proven in action
Hear from the first experts to work with a BioMatrix scanner.
MAGNETOM Vida
Discover how to embrace human nature at 3T.
Benefit from a faster workflow
Features
BioMatrix Sensors
Anticipate motion for high-quality results
Motion is a challenge in MRI. It can significantly decrease image quality, limit scan consistency, and lead to costly rescans. Fully integrated in the system architecture, BioMatrix Sensors capture respiratory, cardiac and head2 motion, which both boosts consistency and frees up the user to select the optimal exam strategy. This combination ensures high-quality results.
Respiratory Sensors automatically detect breathing patterns as soon as the patient lies on the table. This simplifies workflow as operators can perform respiratory-triggered scans without further interaction.
The Beat Sensor is integrated in the BioMatrix Body 12. It is designed for automatic cardiac triggering to accurately capture heart phases without the need for ECG leads.
The Kinetic Sensor in the scanner bore records real-time head motion information. It is designed for prospective motion correction2 and high-quality exams.
BioMatrix Tuners
Adapt to challenging anatomies for reliable exams
BioMatrix Tuners automatically adapt to challenging anatomies such as the head /neck area, the spine and the abdomen, for reliable exams. Even in difficult scan regions, intelligent coil technology consistently delivers excellent homogeneity and fat saturation. This provides robust, reproducible, high-quality imaging – for every patient, every time.
CoilShim technology is built into BioMatrix head and neck coils. It automatically improves fat saturation and DWI quality in the neck region to boost diagnostic quality and reduce the need for repeat scans.
SliceAdjust provides distortion-free, whole-body DWI scans and reliable fat saturation for both DWI and TSE sequences1. It avoids broken spine artifacts for excellent correlation with anatomical scans.
BioMatrix Interfaces
Accelerate patient preparation for increased efficiency
BioMatrix Interfaces simplify how the user interacts with the scanner and the patient, accelerating patient preparation in order to increase quality and improve cost-effectiveness. No matter how tall, big, or mobile a patient is – or how experienced the technologist is – BioMatrix Interfaces speed up the workflow for increased efficiency.
Select&GO lets operators use artificial intelligence to automatically position patients up to 30%1 faster and avoid repositioning delays. The user simply selects the region or organ to be scanned with one touch on the display and the patient is precisely positioned.
The BioMatrix dockable table with eDrive support provides motorized assistance for transferring patients. Now even the heaviest patients can be effortlessly moved to and from the scanner.
Clinical Images
Browse the images to see the difference BioMatrix Technology can make in challenging MRI environments.
Prostate imaging
High resolution prostate imaging without the use of an endorectal coil is possible, even at 1.5T.
- Body 18
- BioMatrix Spine 32
Acquired on
MAGNETOM Sola
RESOLVE
4scan trace & ADC map
Outstanding diagnostic performance with RESOLVE with sharp, high-resolution DWI and DTI of the brain and spine – standard with MAGNETOM Vida.
- BioMatrix Head/Neck 20
Acquired on
MAGNETOM Vida
Ultra-thin 0.86 mm slices achievable with theBioMatrix Head/Neck 64
Acquired on
MAGNETOM Vida
DTI fibertracking 64 directions, post-processed with Neuro 3D
- BioMatrix Head/Neck 64
Acquired on
MAGNETOM Vida
The innovative CoilShim technology integrates shim elements in the new BioMatrix Head/Neck coils, to allow for patient- and region-specific shimming for significantly improved fat saturation and better DWI quality.
- BioMatrix Head/Neck 20 (18° tilt)
Acquired on
MAGNETOM Vida
The innovative CoilShim technology integrates shim elements in the new BioMatrix Head/Neck coils, to allow for patient- and region-specific shimming for significantly improved fat saturation and better DWI quality.
- BioMatrix Head/Neck 20 (18° tilt)
Acquired on
MAGNETOM Vida
Avoid broken spine artifacts in whole spine DWI.
- BioMatrix Spine 32
Acquired on
MAGNETOM Vida
Whole spine T2 in only 2 station
- BioMatrix Spine 32
- BioMatrix Head/Neck 64
Acquired on
MAGNETOM Vida
Brachial plexus 3D T2 SPACE
- BioMatrix Head/Neck 64
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Hip imaging with the new UltraFlex coils
High-resolution bilateral hip imaging with UltraFlex Coils in pediatrics – 8-year-old boy.
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Hip imaging with the new UltraFlex coils
High-resolution unilateral hip imaging at small Field-of-View using the new UltraFlex Coils.
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Long-bone imaging 50 cm z-Field-of-View
Long-bone imaging with excellent fat saturation and image homogeneity in only one step enabled by MAGNETOM Vida's large.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
The new coil offers high-resolution knee imaging with a larger coil opening to accomodate a broader patient population.
- Tx/Rx Knee 18
Acquired on
MAGNETOM Vida
Foot/Ankle imaging
with the new UltraFlex coils
The new coils alllow ultra-high-density orthopedic imaging with the flexibility to apply in various anatomical regions.
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Shoulder imaging
with the new Shoulder Shape 16
T1 TSE and PD FatSat. The Shoulder Shape 16 is a new ultra-high element density coil with innovative, flexible patient adaptive design.
- Shoulder Shape 16
Acquired on
MAGNETOM Vida
3D VIBE Dixon Water
1 station
50 cm z-FoV
Full abdominal coverage from liver dome down to the pelvis allow for comprehensive oncological scans in one station with excellent quality.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
SELLINK imaging
with a large FoV and homogeneous fat saturation
- Body 30
- BioMatrix Spine 32
Acquired on
MAGNETOM Vida
MRCP T2 SPACE
- Body 30
Acquired on
MAGNETOM Vida
Compressed Sensing
GRASP-VIBE
Compressed Sensing GRASP-VIBE for dynamic liver imaging in free-breathing for patients who cannot reliably hold their breath.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
Simultaneous Multi-Slice
Simultaneous Multi-Slice for significantly reduced acquisition time for abdominal diffusion imaging.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
BioMatrix SliceAdjust
Consistent results in the entire imaging volume for multi-breath-hold TSE acquisitions.
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Vida
BioMatrix SliceAdjust
Consistent results in the entire imaging volume for multi-breath-hold TSE acquisitions.
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Sola
BioMatrix Respiratory Sensor
Respiratory triggering without the need for a navigator setup or the application of a breathing belt.
- T2 HASTE
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Vida
Full whole-body coverag5 stations
Excellent whole-body DWI quality due to BioMatrix SliceAdjust
- BioMatrix Head/Neck 20
- 2 x Body 18
- BioMatrix Spine 72
- Peripheral Angio 36
Acquired on
MAGNETOM Vida
BioMatrix Beat Sensor
designed for cardiac triggering4 without the need for ECG
Segmented Cardiac Cine 4-chamber view with BioMatrix Beat Sensor.
- Body 12
- BioMatrix Spine 24
Acquired on
MAGNETOM Sola
- BioMatrix Head/Neck 20
- BioMatrix Spine 32
Acquired on
MAGNETOM Vida
BioMatrix Respiratory Sensor
Respiratory triggering without the need for a navigator setup or the application of a breathing belt.
- NATIVE Angiography of renal arteries
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Vida
Compressed Sensing Cardiac Cine
Compressed Sensing Cardiac Cine for free-breathing Cardiac Cine imaging
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
High-resolution breast MRI
Designed for imaging and biopsy with high SNR in both diagnostic and interventional setup.
- Breast BI 7
Acquired on
MAGNETOM Sola
Prostate imaging
High resolution prostate imaging without the use of an endorectal coil is possible, even at 1.5T.
- Body 18
- BioMatrix Spine 32
Acquired on
MAGNETOM Sola
RESOLVE
4scan trace & ADC map
Outstanding diagnostic performance with RESOLVE with sharp, high-resolution DWI and DTI of the brain and spine – standard with MAGNETOM Vida.
- BioMatrix Head/Neck 20
Acquired on
MAGNETOM Vida
Ultra-thin 0.86 mm slices achievable with theBioMatrix Head/Neck 64
Acquired on
MAGNETOM Vida
DTI fibertracking 64 directions, post-processed with Neuro 3D
- BioMatrix Head/Neck 64
Acquired on
MAGNETOM Vida
The innovative CoilShim technology integrates shim elements in the new BioMatrix Head/Neck coils, to allow for patient- and region-specific shimming for significantly improved fat saturation and better DWI quality.
- BioMatrix Head/Neck 20 (18° tilt)
Acquired on
MAGNETOM Vida
The innovative CoilShim technology integrates shim elements in the new BioMatrix Head/Neck coils, to allow for patient- and region-specific shimming for significantly improved fat saturation and better DWI quality.
- BioMatrix Head/Neck 20 (18° tilt)
Acquired on
MAGNETOM Vida
Avoid broken spine artifacts in whole spine DWI.
- BioMatrix Spine 32
Acquired on
MAGNETOM Vida
Whole spine T2 in only 2 station
- BioMatrix Spine 32
- BioMatrix Head/Neck 64
Acquired on
MAGNETOM Vida
Brachial plexus 3D T2 SPACE
- BioMatrix Head/Neck 64
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Hip imaging with the new UltraFlex coils
High-resolution bilateral hip imaging with UltraFlex Coils in pediatrics – 8-year-old boy.
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Hip imaging with the new UltraFlex coils
High-resolution unilateral hip imaging at small Field-of-View using the new UltraFlex Coils.
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Long-bone imaging 50 cm z-Field-of-View
Long-bone imaging with excellent fat saturation and image homogeneity in only one step enabled by MAGNETOM Vida's large.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
The new coil offers high-resolution knee imaging with a larger coil opening to accomodate a broader patient population.
- Tx/Rx Knee 18
Acquired on
MAGNETOM Vida
Foot/Ankle imaging
with the new UltraFlex coils
The new coils alllow ultra-high-density orthopedic imaging with the flexibility to apply in various anatomical regions.
- UltraFlex Large 18
Acquired on
MAGNETOM Vida
Shoulder imaging
with the new Shoulder Shape 16
T1 TSE and PD FatSat. The Shoulder Shape 16 is a new ultra-high element density coil with innovative, flexible patient adaptive design.
- Shoulder Shape 16
Acquired on
MAGNETOM Vida
3D VIBE Dixon Water
1 station
50 cm z-FoV
Full abdominal coverage from liver dome down to the pelvis allow for comprehensive oncological scans in one station with excellent quality.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
SELLINK imaging
with a large FoV and homogeneous fat saturation
- Body 30
- BioMatrix Spine 32
Acquired on
MAGNETOM Vida
MRCP T2 SPACE
- Body 30
Acquired on
MAGNETOM Vida
Compressed Sensing
GRASP-VIBE
Compressed Sensing GRASP-VIBE for dynamic liver imaging in free-breathing for patients who cannot reliably hold their breath.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
Simultaneous Multi-Slice
Simultaneous Multi-Slice for significantly reduced acquisition time for abdominal diffusion imaging.
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
BioMatrix SliceAdjust
Consistent results in the entire imaging volume for multi-breath-hold TSE acquisitions.
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Vida
BioMatrix SliceAdjust
Consistent results in the entire imaging volume for multi-breath-hold TSE acquisitions.
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Sola
BioMatrix Respiratory Sensor
Respiratory triggering without the need for a navigator setup or the application of a breathing belt.
- T2 HASTE
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Vida
Full whole-body coverag5 stations
Excellent whole-body DWI quality due to BioMatrix SliceAdjust
- BioMatrix Head/Neck 20
- 2 x Body 18
- BioMatrix Spine 72
- Peripheral Angio 36
Acquired on
MAGNETOM Vida
BioMatrix Beat Sensor
designed for cardiac triggering4 without the need for ECG
Segmented Cardiac Cine 4-chamber view with BioMatrix Beat Sensor.
- Body 12
- BioMatrix Spine 24
Acquired on
MAGNETOM Sola
- BioMatrix Head/Neck 20
- BioMatrix Spine 32
Acquired on
MAGNETOM Vida
BioMatrix Respiratory Sensor
Respiratory triggering without the need for a navigator setup or the application of a breathing belt.
- NATIVE Angiography of renal arteries
- BioMatrix Spine 32
- Body 18
Acquired on
MAGNETOM Vida
Compressed Sensing Cardiac Cine
Compressed Sensing Cardiac Cine for free-breathing Cardiac Cine imaging
- Body 18
- BioMatrix Spine 72
Acquired on
MAGNETOM Vida
High-resolution breast MRI
Designed for imaging and biopsy with high SNR in both diagnostic and interventional setup.
- Breast BI 7
Acquired on
MAGNETOM Sola
Prostate imaging
High resolution prostate imaging without the use of an endorectal coil is possible, even at 1.5T.
- Body 18
- BioMatrix Spine 32
Acquired on
MAGNETOM Sola
Clinical Cases
Discover how other MRI experts have applied BioMatrix Technology and the benefits this has brought.
MAGNETOM Flash – BioMatrix special issue
Read how colleagues worldwide face today's challenges in MRI with BioMatrix Technology and syngo MR XA software.
Spotlight on variation reduction
Experts at University Hospital Mannheim assess the MRI system MAGNETOM Sola with BioMatrix Technology.
Learn more about BioMatrix Technology with these BioMatrix-specific case studies and clinical talks at MAGNETOM World, the Siemens MR user community forum.
Systems
Scanners with BioMatrix Technology
The family of scanners equipped with BioMatrix Technology is growing fast. Compare key specifications to find the perfect match for your needs.