Viva-ProE System

Proven performance in a reliable, next-generation benchtop system

Designed for clinical laboratories, transplant-management centers, workplace testing, pre-employment testing centers, drug courts, criminal justice systems, and treatment centers, Viva-ProE® System helps optimize your facility’s drug-testing capabilities by delivering efficient results in a compact benchtop design.

  • Proven performance using trusted Syva® EMIT® technology for drugs-of-abuse testing/toxicology, therapeutic drug monitoring, and validity testing
  • Improved workflow and workstation efficiency plus greater ease of use—all in one powerful benchtop system
  • Complete menu of reliable EMIT assays to help make confident decisions with minimal turnaround time
Viva-ProE® System

Benefits

Viva-ProE® System – reliable performance
  • Uses EMIT technology—the standard in assay performance for results you can trust.
  • Enables testing of a complete menu of proven EMIT assays to help make confident decisions with minimal turnaround time.
  • Delivers proven reliability with robust, durable components that provide longer uptime.
  • Employs advanced instrumentation and intuitive integrated software to reduce user maintenance and limit maintenance visits to one per year.
Viva-ProE® System – innovative technologies
  • Semicontinuous sample loading and true random-access capability for routine and STAT samples
  • Liquid, ready-to-use, onboard reagents to help minimize hands-on time and eliminate errors associated with manual reagent preparation
  • Unique sample and reagent probes with built-in technologies for safe system operation and result management, including liquid-level sensors, crash protection, and precision monitoring to help deliver fast, reliable results
  • Efficient Peltier cooling for reagent stability and performance
Viva-ProE® System – comprehensive but compact
  • Provides full sampling power without the full footprint.
  • 10 open channels allow flexible test menu and assay capacity.
  • 50 sample positions support true walkaway time while reducing potential for error.
Viva-ProE® System – intuitive and easy to use
  • Touchscreen command center with intuitive workflow software to further aid in improving lab efficiencies
  • Easy procedural checklist guides to assist operators in their day-to-day workflow
  • Onboard operator’s manual with instructions for reagent inventory management and general troubleshooting
Viva-ProE® System – complete drug-testing menu
  • Consolidated drug-testing menu for drugs of abuse, serum toxicology, and therapeutic and immunosuppressant drug monitoring gives even the smallest lab access to proven EMIT testing.
  • Supports five specimen validity tests to help you determine if you are testing a valid urine sample.
Viva-ProE® System – reliable performance
  • Uses EMIT technology—the standard in assay performance for results you can trust.
  • Enables testing of a complete menu of proven EMIT assays to help make confident decisions with minimal turnaround time.
  • Delivers proven reliability with robust, durable components that provide longer uptime.
  • Employs advanced instrumentation and intuitive integrated software to reduce user maintenance and limit maintenance visits to one per year.

Assays

Complete menu for drugs-of-abuse and validity testing and serum toxicology

Download full menu

Drugs of Abuse/Toxicology

26
6-Acetylmorphine (6-AM)*
Amphetamines
Barbiturates
Benzodiazepines
Benzodiazepines (High-sensitivity)†,**
Buprenorphine
Cannabinoids
Cocaine Metabolite
Ecstasy
EDDP
Ethyl Alcohol
Ethyl Glucuronide (EtG)†‡
Fentanyl
Hydrocodone†,††,‡‡
Ketamine†‡
Lysergic Acid Diethylamide(LSD)
Meperidine†‡
Methadone
Methamphetamine*
Methaqualone
Opiates
Oxycodone
Phencyclidine
Propoxyphene
Synthetic Cannabinoids†‡
Tramadol

Therapeutic Drug Monitoring

28
Amikacin
Caffeine
Carbamazepine
Cyclosporine
Digoxin
Disopyramide
Ethosuximide
Gabapentin§§
Gentamicin
Lamotrigine§§
Levetiracetam§§
Lidocaine
Methotrexate
Mycophenolic Acid**
Phenobarbital
Phenytoin
Primidone
Procainamide
Quinidine
Sirolimus
Tacrolimus
Theophylline
Tobramycin
Topiramate§§
Valproic Acid
Vancomycin
Voriconazole§§
Zonisamide§§

EMIT Serum Toxicology

5
Acetaminophen
Barbiturates
Benzodiazepines
Salicylic Acid
Tricyclic Antidepressants

Specimen Validity Test

5
Creatinine
Nitrites
Oxidants
pH
Specific Gravity

Syva RapidTest

10
Amphetamines
Barbiturates
Benzodiazepines
Cannabinoids
Cocaine Metabolite
Methadone
Methamphetamine
Opiates
Phencyclidine
Tricyclic Antidepressants

Technical Details

Technical Specifications

Throughput

Up to 133 EMIT tests per hour with two reagents
Up to 65 EMIT tests per hour with three reagents

Reagent system

  • EMIT reagent rotor — with 13 positions for 14 mL bottles and 13 positions for 28 mL bottles
  • All positions in both rotors can be assigned as R1, R2, and R3
  • The reagent rotor compartment is cooled to 8–12°C (absolute up to 25°C ambient temperature)
  • Reagent volumes:
    • Reagent 1 volume 110–399 μL
    • Reagent 2 volume 10–289 μL
    • Reagent 3 volume 10–289 μL

Aspirated reagents are heated, with level detector and integrated stirrer

Sample system – providing semi-continuous loading

Sample rotor contains:

  • 50 positions for barcoded tubes
  • 12 positions for tubes without barcodes
  • 1 blank and 1 washing position
Download technical specifications

*
§
**
††
‡‡
§§