CLINITEK Status® Connect System

CLINITEK Status® Connect SystemNeed more control over your point-of-care urinalysis testing process?

CLINITEK Status® Connect System simplifies wireless or wired connectivity and testing oversight in point-of care urinalysis for improved risk management.

  • Offers flexible connectivity solutions by integrating data directly to the LIS, EMR or via point-of-care data management software solutions
  • Provides improved POC testing workflow efficiencies when interfaced to leading data management solutions
  • Improved barcode response time allows quick entry of lot and expiration data with a single scan.
  • Improves risk management through advanced operator control functions, prevents unauthorized use
  • Drives compliance across testing sites with programmable QC protocols and QC lockout
  • Auto-Checks* help to ensure the quality and accuracy of data while facilitating an enhanced interpretation of results.
  • Features & Benefits

    Centralize control over your point-of-care urinalysis testing program with the CLINITEK Status Connect

    Supports Flexible & Efficient Connectivity

    • Connect to your hospital’s LIS/HIS, EMR or point-of-care middleware solution
    • Connects by wireless, Ethernet or serial transmission
    • Supports HL7 and POCT1-A2 protocols
    • Interfaces with leading point-of-care data management solutions for centralized control and testing oversight - including Siemens’ RAPIDComm® Data Management System and Connectivity Solution; Conworx Technology POCcelerator; MAS RALS®-Plus; TELCOR Quick-Linc®

    Advanced Operational Control and Management

    • Provides customized operator access level
    • Supports operator ID entry and lockout
    • Prevents unauthorized use, based on customizable settings

    Enhanced Quality Control

    • Optional barcode reader eliminates manual steps and reduces transcription errors
    • Maintain up-to-date operator certification records and restrict operator access as needed
    • Define specific QC protocols for operators across multiple sites
    • QC lockout if protocol is not followed or QC test fails
    • QC documentation and report downloads are available on demand
    • Store up to 200 QC test records

    Improved Data Integrity

    Auto-Checks:

    • Checks each strip for humidity to prevent reporting of falsely elevated results
    • Detects interferences in test samples and provides printed notation for improved results interpretation
    • Identifies Siemens strip type to save time

    Assays

    The CLINITEK Status Connect System provides automated reading of the Multistix® family of urinalysis tests:

    • Leukocyte
    • Nitrite
    • Protein
    • Blood
    • Glucose
    • Ketone
    • Bilirubin
    • Urobilinogen
    • pH
    • Specific Gravity
    • Creatinine
    • Protein-to-Creatinine Ratio
    • Albumin
    • Albumin-to-Creatinine Ratio (ACR)
    • CLINITEST® hCG Pregnancy Test 

    Technical Specifications

    Semi-quantitative Tests Measured
    Routine urine tests
    albumin, bilirubin, creatinine, glucose, ketone, leukocytes, nitrite, pH, protein, specific gravity and urobilinogen
    Kidney disease test
    albumin-to-creatinine ratio
    Pregnancy test
    Human Chorionic Gonadotropin (hCG)

    General Specifications

    Depth
    10.7 in. or 27.2 cm
    Width
    6.7 in. or 17.1 cm
    Height
    7.5 in. or 18.5 cm
    Weight
    5.0 lbs or 2.3 kg
    Electrical rating
    100V - 240V AC, 50-60 Hz (with in-line lead)
    Battery operation
    Not available
    Ambient temperature range
    18 to 30ºC (64 to 86ºF)
    Humidity range
    18-80% relative humidity, non-condensing
    Compliance
    UL, CE, EMC
    Calibration
    automatic, self-calibrating

    Communication Capabilities

    Communication protocol
    HL7, POCT1-A2
    Data transmission options
    wireless, Ethernet or serial connection
    Interfaces with leading point-of-care
    data management solutions*
    • Siemens’ RAPIDComm® Data Management and Connectivity Solution
    • MAS RALS®-Plus
    • Telcor Quick-Linc®
    • POCcelerator™


    Memory

    Patient test results
    700
    QC test results
    200
    Operator IDs
    700

    Quality Control Management Features

    QC testing and reporting

    QC reminders or mandatory prompt

    QC lockout


    Barcode Data Entry

    Patient ID, operator ID and name,
    QC control type, lot number, and expiration date


    Barcode Symbology Supported

    Code 93, Code 39 (with and without check digit), Code 128, Coda Bar, Interleaved 2 of 5 (with and without check digit)


    Operator Security Features

    Define up to 700 operators

    Operator lock-out to prevent unauthorized use

    Customize access level for each operator for the following functions:
    • Performing patient tests
    • Performing QC tests
    • Recalling results
    • Modifying system settings