- The SOMATOM go. platform – Made to match
The SOMATOM go. platform with myExam Companion Made to match.
Clinical trends and guidelines change. Your needs evolve. Our solutions evolve. In the SOMATOM® go. platform, both come together. From routine to advanced procedures, the new platform offers the right CT scanner for your clinical tasks. Each scanner features innovations that make it smarter and even more patient-centric:
- The latest AI-supported workflows
- Expanded clinical capabilities
- Seamless integration in our products and digital services
Smart – intelligent tools to match your workflows
Even as CT scanner staff numbers fall, the demands on them are rising. To support users in their daily work and help them meet radiologists’ expectations, the SOMATOM go. platform features myExam Companion, providing AI-supported guidance to patients and operators throughout the workflow and driving consistency in exam setup and image quality.
Flexible – performance to match your clinical needs
As CT becomes ever more relevant, institutions must be able to handle a broad variety of tasks and patients – including those requiring complex and specialized procedures. Each of the four SOMATOM go. platform CT scanners helps you tackle your specific clinical setup and tasks so you can optimally adapt to each patient and produce consistent results for a diverse patient mix.
Productive – a smart investment to match your goals
When purchasing a CT scanner, there is more than just the equipment cost to consider. With the SOMATOM go. platform, you benefit from reduced lifecycle costs, new reimbursement opportunities, and a connected fleet.
Meet the platform
SOMATOM go.Now
is a robust and reliable system that provides access to CT imaging. Benefit from high image quality at low dose to level up you imaging capabilities.
SOMATOM go.Up
is a scanner designed for daily routine that helps you adhere to clinical guidelines. Handle high throughput and challenging cases with ease.
SOMATOM go.All
is a scanner that unlocks more than routine – covering daily procedures and ready for more advanced ones when needed.
SOMATOM go.Top
is a clinical allrounder that gives you full flexibility in your clinical tasks. Handle all routine procedures and the most important advanced ones to cater to a wider range of patients.
Clinical case gallery
Abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Now
Collimation: 16 x 0.7 mm (each)
Scan time: 22 s (each)
Scan length: 316 mm (each)
Rotation time: 0.8 s (each)
Pitch factor: 1.0 (each)
Scan parameters: 130 kV / 123 mAs (each)
CTDIvol: 8.85 mGy (each)
DLP: 268 mGy cm (each)
- 2 mm axial MPR shown for native, arterial, portal-venous and delayed scans
- Prevent subsequent errors in multiphase scans, and avoid archiving of suboptimal images with Check&GO
Skull base / sinus imaging with Tin Filter
SOMATOM go.Now
Collimation: 16 x 0.7 mm
Scan time: 15 s
Scan length: 107 mm
Rotation time: 1.0 s
Pitch factor: 0.55
Scan parameters: 110 kV / 125 mAs
CTDIvol: 8.05 mGy
DLP: 65 mGy cm
- 0.6 mm reconstructions thanks to Stellar detector technology
- Small bony structures sharply visualized with a balanced imaging chain:
Chronon® + Stellar + SAFIRE
Pulmonary hematoma
SOMATOM go.Now
Collimation: 16 x 0.7 mm
Scan time: 14 s
Scan length: 324 mm
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 130 kV / 188 mAs
CTDIvol: 8.24 mGy
DLP: 255.9 mGy cm
- Stellar detector enables fine visualization of details
- Stellar detector lowers image noise and enhances scan results
Abdomen imaging with i.v. contrast media application 1/2
SOMATOM go.Now
Collimation: 16 x 0.7 mm (each)
Scan time: 22 s (each)
Scan length: 316 mm (each)
Rotation time: 0.8 s (each)
Pitch factor: 1.0 (each)
Scan parameters: 130 kV / 123 mAs (each)
CTDIvol: 8.85 mGy (each)
DLP: 268 mGy cm (each)
- 2 mm axial MPR shown for arterial scans for the scan volume
- Coronal thick slice MIP for portal-venous scans for visualization of the portal vein
Abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Now
Collimation: 16 x 0.7 mm (each)
Scan time: 22 s (each)
Scan length: 316 mm (each)
Rotation time: 0.8 s (each)
Pitch factor: 1.0 (each)
Scan parameters: 130 kV / 123 mAs (each)
CTDIvol: 8.85 mGy (each)
DLP: 268 mGy cm (each)
- 2 mm axial MPR shown for native, arterial, portal-venous and delayed scans
- Prevent subsequent errors in multiphase scans, and avoid archiving of suboptimal images with Check&GO
Skull base / sinus imaging with Tin Filter
SOMATOM go.Now
Collimation: 16 x 0.7 mm
Scan time: 15 s
Scan length: 107 mm
Rotation time: 1.0 s
Pitch factor: 0.55
Scan parameters: 110 kV / 125 mAs
CTDIvol: 8.05 mGy
DLP: 65 mGy cm
- 0.6 mm reconstructions thanks to Stellar detector technology
- Small bony structures sharply visualized with a balanced imaging chain:
Chronon® + Stellar + SAFIRE
Pulmonary hematoma
SOMATOM go.Now
Collimation: 16 x 0.7 mm
Scan time: 14 s
Scan length: 324 mm
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 130 kV / 188 mAs
CTDIvol: 8.24 mGy
DLP: 255.9 mGy cm
- Stellar detector enables fine visualization of details
- Stellar detector lowers image noise and enhances scan results
Abdomen imaging with i.v. contrast media application 1/2
SOMATOM go.Now
Collimation: 16 x 0.7 mm (each)
Scan time: 22 s (each)
Scan length: 316 mm (each)
Rotation time: 0.8 s (each)
Pitch factor: 1.0 (each)
Scan parameters: 130 kV / 123 mAs (each)
CTDIvol: 8.85 mGy (each)
DLP: 268 mGy cm (each)
- 2 mm axial MPR shown for arterial scans for the scan volume
- Coronal thick slice MIP for portal-venous scans for visualization of the portal vein
Abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Now
Collimation: 16 x 0.7 mm (each)
Scan time: 22 s (each)
Scan length: 316 mm (each)
Rotation time: 0.8 s (each)
Pitch factor: 1.0 (each)
Scan parameters: 130 kV / 123 mAs (each)
CTDIvol: 8.85 mGy (each)
DLP: 268 mGy cm (each)
- 2 mm axial MPR shown for native, arterial, portal-venous and delayed scans
- Prevent subsequent errors in multiphase scans, and avoid archiving of suboptimal images with Check&GO
Peripheral run-off CT angiography
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 28 s
Scan length: 1198 mm u
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 110 kV
CTDIvol: 4.48 mGy
DLP: 526 mGy cm
- Fine visualization of peripheral vessels
- Automatic Recon&GO inline results
Brain imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Brain imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s u
Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Adding Tin Filter technology to your clinical daily rotuine low dose lung protocol
SOMATOM go.Up
Scan time: 9 s
Scan length: 33 cm
Pitch: 0.8
Rotion time: 0.5 s
Sn110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- Profit from high density of detector channels
- High image quality combined with optimized radiation dose with Tin filter
Combining high pitch and fast rotation time for high resolution lung Imaging
SOMATOM go.Up
Scan time: 6 s
Scan length: 32 cm
Pitch: 1.2
Rotion time: 0.5 s
110 kV
CTDIvol: 3.46 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- High image quality with perfectly attuned imaging chain and SAFIRE reconstructions
Pulmonary embolism evaluation in emmergency setting
SOMATOM go.Up
Scan time: 7 s
Scan length: 38 cm
Pitch: 1.15
Rotion time: 0.5 s
110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- High pitch and fast rotation for optimizing scan time
- Delivering excellent image quality in daily clinical relevance
Two-step thorax and abdomen imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax) 21 s (abdomen)
Scan length: 392 mm (thorax) 502 mm (abdomen)
Rotation time: 0.8 s (each)
Pitch factor: 0.8 (each)
Scan parameters: 130 kV / 58 mAs (thorax); 130 kV / 98 mAs (abdomen)
CTDIvol: 5.37 mGy (thorax) 10.5 mGy (abdomen)
DLP: 197 mGy cm (thorax) 502 mGy cm (abdomen)
- Follow-up after partial liver resection
- Multi-step CT protocol
Two-step thorax and abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax)
Scan length: 392 mm (thorax)
Rotation time: 0.8 s
Pitch factor: 0.8
Scan parameters: 130 kV / 58 mAs (thorax)
CTDIvol: 5.37 mGy (thorax)
DLP: 197 mGy cm (thorax)
- VRT based on thoracic spiral
- Confirm correct organ coverage and contrast agent distribution with Check&GO
Peripheral run-off CT angiography
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 28 s
Scan length: 1198 mm u
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 110 kV
CTDIvol: 4.48 mGy
DLP: 526 mGy cm
- Fine visualization of peripheral vessels
- Automatic Recon&GO inline results
Brain imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Brain imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s u
Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Adding Tin Filter technology to your clinical daily rotuine low dose lung protocol
SOMATOM go.Up
Scan time: 9 s
Scan length: 33 cm
Pitch: 0.8
Rotion time: 0.5 s
Sn110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- Profit from high density of detector channels
- High image quality combined with optimized radiation dose with Tin filter
Combining high pitch and fast rotation time for high resolution lung Imaging
SOMATOM go.Up
Scan time: 6 s
Scan length: 32 cm
Pitch: 1.2
Rotion time: 0.5 s
110 kV
CTDIvol: 3.46 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- High image quality with perfectly attuned imaging chain and SAFIRE reconstructions
Pulmonary embolism evaluation in emmergency setting
SOMATOM go.Up
Scan time: 7 s
Scan length: 38 cm
Pitch: 1.15
Rotion time: 0.5 s
110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- High pitch and fast rotation for optimizing scan time
- Delivering excellent image quality in daily clinical relevance
Two-step thorax and abdomen imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax) 21 s (abdomen)
Scan length: 392 mm (thorax) 502 mm (abdomen)
Rotation time: 0.8 s (each)
Pitch factor: 0.8 (each)
Scan parameters: 130 kV / 58 mAs (thorax); 130 kV / 98 mAs (abdomen)
CTDIvol: 5.37 mGy (thorax) 10.5 mGy (abdomen)
DLP: 197 mGy cm (thorax) 502 mGy cm (abdomen)
- Follow-up after partial liver resection
- Multi-step CT protocol
Two-step thorax and abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax)
Scan length: 392 mm (thorax)
Rotation time: 0.8 s
Pitch factor: 0.8
Scan parameters: 130 kV / 58 mAs (thorax)
CTDIvol: 5.37 mGy (thorax)
DLP: 197 mGy cm (thorax)
- VRT based on thoracic spiral
- Confirm correct organ coverage and contrast agent distribution with Check&GO
Peripheral run-off CT angiography
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 28 s
Scan length: 1198 mm u
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 110 kV
CTDIvol: 4.48 mGy
DLP: 526 mGy cm
- Fine visualization of peripheral vessels
- Automatic Recon&GO inline results
Evaluation of coronaries in a high risk patient ECG-gated spiral 3/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- Automated, zero-click reconstruction of CPRs
Rule-out of bleeding and vascular status clarification
Non-contrast and contrast-enhanced brain CTA scan
SOMATOM go.All
Scan time: 13 / 2 s
Scan length: 185 / 192 mm 120 / 80 kV
CTDIvol: 38.4 / 6.3 mGy
DLP: 603 / 103 mGy cm
- Optimal low-contrast performance for differentiation of gray/white matter
- Powerful low-kV imaging
Evaluation of severe peripheral vessel disease Run-off CTA after bypass surgery
SOMATOM go.All
Scan time: 30 s
Scan length: 1223 mm 80 kV
CTDIvol: 3.16 mGy
DLP: 399 mGy cm
- Contrast enhancement even in distal vasculartue with 80kV
Evaluation of trunk to rule-out pathologies Single phase contrast-media-enhanced scan
SOMATOM go.All
Scan time: 17 s
Scan length: 614 mm 110 kV
CTDIvol: 6.14 mGy
DLP: 281 mGy cm
- Ease all your CT demands with flexible kV settings and automated reconstruction
- Optimal results thanks to Stellar detector
Evaluation of coronaries in a high risk patient ECG-gated spiral 1/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- 165 ms temporal resolution for great acquisition and visualization of the heart and its coronary arteries
Evaluation of coronaries in a high risk patient ECG-gated spiral 2/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm
110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- CARE kV in combination with the 10 kV steps and automated Best Phase detection
Evaluation of coronaries in a high risk patient ECG-gated spiral 3/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- Automated, zero-click reconstruction of CPRs
Rule-out of bleeding and vascular status clarification
Non-contrast and contrast-enhanced brain CTA scan
SOMATOM go.All
Scan time: 13 / 2 s
Scan length: 185 / 192 mm 120 / 80 kV
CTDIvol: 38.4 / 6.3 mGy
DLP: 603 / 103 mGy cm
- Optimal low-contrast performance for differentiation of gray/white matter
- Powerful low-kV imaging
Evaluation of severe peripheral vessel disease Run-off CTA after bypass surgery
SOMATOM go.All
Scan time: 30 s
Scan length: 1223 mm 80 kV
CTDIvol: 3.16 mGy
DLP: 399 mGy cm
- Contrast enhancement even in distal vasculartue with 80kV
Evaluation of trunk to rule-out pathologies Single phase contrast-media-enhanced scan
SOMATOM go.All
Scan time: 17 s
Scan length: 614 mm 110 kV
CTDIvol: 6.14 mGy
DLP: 281 mGy cm
- Ease all your CT demands with flexible kV settings and automated reconstruction
- Optimal results thanks to Stellar detector
Evaluation of coronaries in a high risk patient ECG-gated spiral 1/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- 165 ms temporal resolution for great acquisition and visualization of the heart and its coronary arteries
Evaluation of coronaries in a high risk patient ECG-gated spiral 2/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm
110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- CARE kV in combination with the 10 kV steps and automated Best Phase detection
Evaluation of coronaries in a high risk patient ECG-gated spiral 3/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- Automated, zero-click reconstruction of CPRs
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 3/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Automated results
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 1/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- CARE kV combined with 10 kV Steps
- Automated, zero-click reconstruction of CPRs
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 2/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- Optimal image quality due to CARE kV in 10 kV Steps
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Evaluation of vascular territories Flex 4D Spiral scan
SOMATOM go.Top
Scan time: 41.8 s
Scan length: 58 mm 70 kV
CTDIvol: 145.8 mGy
DLP: 1604 mGy cm
- Flexible handling of 4D perfusion scans thanks to Flex 4D Spiral
- 70 kV for improved contrast to noise ratio
- Achieve a scan range of up to 8.4 cm with cycle time of 1.5 s
Trauma patient Native whole-body evaluation
SOMATOM go.Top
Scan time: 21 s
Scan length: 1875 mm 120 kV
CTDIvol: 6.08 mGy
DLP: 1175 mGy cm
- High resolution throughout the long scan range thanks to Stellar detector and powerful Athlon tube
- Automated result creation with Recon&GO
Evaluation of pancreatic mass Multi-phase including TwinBeam Dual Energy abdomen CT scan
SOMATOM go.Top
Scan time: 3 / 2 / 14 s
Scan length: 265 / 232 / 518 mm
110 / 130 / AuSn120 kV
CTDIvol: 6.7 / 7 / 6.1 mGy
DLP: 181 / 165 / 292 mGy cm
- Advanced diagnostic image quality enabled by high-contrast applications
- Zero-click postprocessingwith TwinBeam Dual Energy inline results
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 1/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Contrast media enhancement due to 70 kV imaging for all types of applications
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 2/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- High-resolution imaging with 1 mm MPRs thanks to Stellar detector and high numbers of projection
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 3/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Automated results
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 1/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- CARE kV combined with 10 kV Steps
- Automated, zero-click reconstruction of CPRs
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 2/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- Optimal image quality due to CARE kV in 10 kV Steps
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Evaluation of vascular territories Flex 4D Spiral scan
SOMATOM go.Top
Scan time: 41.8 s
Scan length: 58 mm 70 kV
CTDIvol: 145.8 mGy
DLP: 1604 mGy cm
- Flexible handling of 4D perfusion scans thanks to Flex 4D Spiral
- 70 kV for improved contrast to noise ratio
- Achieve a scan range of up to 8.4 cm with cycle time of 1.5 s
Trauma patient Native whole-body evaluation
SOMATOM go.Top
Scan time: 21 s
Scan length: 1875 mm 120 kV
CTDIvol: 6.08 mGy
DLP: 1175 mGy cm
- High resolution throughout the long scan range thanks to Stellar detector and powerful Athlon tube
- Automated result creation with Recon&GO
Evaluation of pancreatic mass Multi-phase including TwinBeam Dual Energy abdomen CT scan
SOMATOM go.Top
Scan time: 3 / 2 / 14 s
Scan length: 265 / 232 / 518 mm
110 / 130 / AuSn120 kV
CTDIvol: 6.7 / 7 / 6.1 mGy
DLP: 181 / 165 / 292 mGy cm
- Advanced diagnostic image quality enabled by high-contrast applications
- Zero-click postprocessingwith TwinBeam Dual Energy inline results
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 1/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Contrast media enhancement due to 70 kV imaging for all types of applications
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 2/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- High-resolution imaging with 1 mm MPRs thanks to Stellar detector and high numbers of projection
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 3/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Automated results
Technical details
SOMATOM go.Now
Slices | 16 (32 with IVR) |
z-Coverage | 16 x 0.7 mm |
Max. mA | 240 mA (400 mA8) |
Tube | 3.5 MHU |
Rotation time | Up to 0.5 s1 |
Power | 32 kW |
kV | 80, 110, 130 kV |
Table load | 160 kg (opt. 227 kg) |
Bore size | 70 cm |
SOMATOM go.Up
Slices | 32 (64 with IVR) |
z-Coverage | 32 x 0.7 mm |
Max. mA | 240 mA (400 mA8) |
Tube | 3.5 MHU |
Rotation time | Up to 0.5 s 1 |
Power | 32 kW |
kV | 80, 110, 130 kV |
Table load | 227 kg (opt. 307 kg) |
Bore size | 70 cm |
SOMATOM go.All
Slices | 32 (64 with IVR) |
z-Coverage | 32 x 0.7 mm |
Max mA | 625 mA (825 mA9) |
Tube | 7.0 MHU |
Rotation time | Up to 0.33 s1 |
Power | 75 kW |
kV | 70, 80, 90, 100, 110, 120, 130, 140 kV |
Table load | Up to 307 kg1 |
Bore size | 70 cm |
SOMATOM go.Top
Slices | 64 (128 with IVR) |
z-Coverage | 64 x 0.6 mm |
mA | 625 mA (825 mA9) |
Tube | 7.0 MHU |
Rotation time | Up to 0.33 s1 |
Power | 75 kW |
kV | 70, 80, 90, 100, 110, 120, 130, 140 kV |
Table load | Up to 307 kg1 |
Bore size | 70 cm |
Are you interested in buying a new CT scanner?
Please contact us for more details and prices for SOMATOM go. scanners.
High Power 80 available for SOMATOM go.Now and SOMATOM go.Up
Chronon® X-ray tube available for SOMATOM go.Now and SOMATOM go.Up
From generation to detection; Dr. Marcus Brehm; Published by Siemens Healthcare GmbH, 2021