ACUSON SC2000 PRIME Ultrasound SystemPrecision at the Speed of Life

The applications for precise cardiac echo continue to grow. The ACUSON SC2000 PRIME is the cardiovascular ultrasound solution that performs 2D and 3D transthoracic (TTE), transesophageal (TEE) and intracardiac echocardiography (ICE) to handle all your cardiovascular imaging needs providing the precision and speed clinicians require today.

Features & Benefits


ACUSON SC2000

The ACUSON SC2000 PRIME ultrasound system provides superior image quality with IN Focus and real-time True Volume imaging and increases productivity with AI-powered one-click measurements, automated protocols and navigational tools.

Power of the platform
Our most powerful echocardiography system, the ACUSON SC2000 PRIME, with its 64 parallel beams (four times more than conventional technology) provides two platform defining features: IN Focus coherent technology and True Volume B-mode and volume color Doppler imaging.

Support your growing imaging needs
The ACUSON SC2000 PRIME is the system that can perform 2D and 3D TTE, TEE and ICE to handle all your cardiovascular imaging needs. This versatile system can be utilized throughout all stages of patient management to improve workflow, maximize system utilization and support more exams and interventions.

Imaging performance
IN Focus coherent technology provides focus at every pixel, at every depth all the time for better spatial resolution, precise border definition, and blood flow visualization — without compromising frame rate.

Visualize the heart in real-time with True Volume B-mode and volume color Doppler imaging, providing real-time assessment of anatomy and physiology at clinically relevant volume size and volume rates without stitching, which is essential for diagnosis and SHD interventions.

Comprehensive suite of quantification tools
Decrease variability with one-click automated AI-powered knowledge-based measurement. The ACUSON SC2000PRIME offers over 200 automated measurements for TTE and TEE exams. 

Expand clinical insights with multi-modality imaging
TrueFusion* integrates advanced ultrasound and angiographic imaging for improved navigation and guidance during structural heart disease interventions. 

  • Confidently guide interventions with markers and valve models overlaid on live fluoroscopy using real-time True Volume and volume color Doppler
  • Help improve communication between echocardiographer and interventionalists with a true integration of echo and angio imaging
  • Simplify your workflow with potentially lower dose, contrast and procedure time

Offline analysis
Siemens Healthineers offers four offline workplace solutions: syngo® SC2000 Workplace, syngo® Ultrasound Apps Suite and syngo® Dynamics. These solutions provide a range of customizable options to enable offline analysis, whenever and wherever needed.

Smart Remote Service
Siemens Healthineers offers Smart Remote Service (SRS) to enable faster resolution time and overall increased productivity through eSieLink remote assistance technology. This service allows clinicians to work more confidently with access to support when and where they need it.

 

Clinical Use

The ACUSON SC2000 PRIME ultrasound system is the platform that is capable to handle all your cardiovascular imaging needs – from 2D and 3D TTE, to TEE and ICE imaging. This versatile system can be utilized throughout all stages of patient management to improve workflow, maximize system utilization, and support more exams and interventions.

Apical 4-chamber view with  IN Focus on the 8V3 transducer.
Apical 4-chamber view with IN Focus on the 8V3 transducer.
LV mass measurement in 2D PLAX view with 4V1c transducer.
LV mass measurement in 2D PLAX view with 4V1c transducer.
Left ventricular analysis (LVA) performed on a dilated heart imaged with the Z6Ms True Volume TEE transducer.
Left ventricular analysis (LVA) performed on a dilated heart imaged with the Z6Ms True Volume TEE transducer.
Apical 4-chamber view showing inflow with Transthoracic impedance respirometer (TIR) with 4V1c transducer.
Apical 4-chamber view showing inflow with Transthoracic impedance respirometer (TIR) with 4V1c transducer.
One-click measurement of VTI on a CW Doppler trace of mitral regurgitation (MR) obtained with Z6Ms True Volume TEE using eSie Measure package.
One-click measurement of VTI on a CW Doppler trace of mitral regurgitation (MR) obtained with Z6Ms True Volume TEE using eSie Measure package.
Results displayed for multibeat strain analysis with VVI technology.
Results displayed for multibeat strain analysis with VVI technology.
Mitral and Aortic valve imaged using Volume color Doppler with True Volume TEE
Mitral and Aortic valve imaged using Volume color Doppler with True Volume TEE

Combine real-time anatomical data from echo overlaying markers and valve models on the fluoro image with TrueFusion Echo-Fluoro Guidance with the Z6Ms true volume transducer.
Combine real-time anatomical data from echo overlaying markers and valve models on the fluoro image with TrueFusion Echo-Fluoro Guidance with the Z6Ms true volume transducer.