Symbia Pro.specta with myExam CompanionModernize to MAXIMIZE
Setting new standards for SPECT/CT, Symbia Pro.specta™ with myExam Companion™1 takes your nuclear medicine department into the future. Every system includes intelligent SPECT/CT imaging and a fully integrated, intuitive user interface to give you more.
- More detail - Fast, low-dose CT with 32 to 64 slices provides more detail.
- More clarity - Automatic SPECT motion correction delivers more clarity.
- More freedom - A smart workflow creates more freedom to focus on patients.
- More flexibility - Specialized tools offer more flexibility to meet expanding clinical needs.
![SPECT CT scan machine - Symbia Pro.specta SPECT/CT](https://marketing.webassets.siemens-healthineers.com/bf17aef60c2355d7/9c464fccc487/v/6abf62a28b86/siemens-healthineers_mi_symbia_pro.specta_spect-ct.jpg)
Benefits
Ready for anything, Symbia Pro.specta with myExam Companion sets new standards for SPECT/CT. Every system delivers high image quality. Every system is quantification- and theranostics-ready. And every system is inherently low dose.
Reach your full potential with a system that fully integrates SPECT and CT. myExam Companion is a single, intuitive interface that guides you through the entire imaging process—resulting in consistent, reproducible results.
Symbia Pro.specta is the most versatile SPECT/CT on the market for routine clinical use.2 Customize your system for virtually every clinical indication, including cardiology, oncology, neurology, orthopedics, and more.
Choose from three theranostics package options designed to optimize quantitative imaging at all energy levels. Every Symbia Pro.specta system features collimators specifically designed for each SPECT isotope.3
A realistic fit in your existing space,4 Symbia Pro.specta's sleek design, modern technologies, and SmartFit configuration options give you more freedom to decide what's possible with SPECT/CT.
Evidence
![Siemens Healthineers theranostics prostate cancer](https://marketing.webassets.siemens-healthineers.com/feedea23e771b79b/85a29a35bb7e/v/05160380897f/siemens-healthineers_mi_theranostics_prostate-cancer.png)
Optimized imaging for theranostics
Every Symbia Pro.specta system is theranostics-ready and features the only SPECT crystal technology clinically proven to manage all SPECT energies reliably, and collimators specifically designed for each isotope.3 These technologies, together with quantification solutions that are precise and reproducible, give you full theranostics capabilities.
Customer voices
Symbia Pro.specta users share their insights about image quality, ease of use, dose reduction, clinical versatility, and more.
![The Symbia Pro.specta in Helsinki was installed in 2022 as the second in Europe for clinical use. “I think it was exciting for us all,” said Reijonen.](https://marketing.webassets.siemens-healthineers.com/5aeb479e46861e70/6b9ca3fe5d28/v/29ddea691f56/siemens-healthineers_mi_symbia_pro.specta_theranostics-program-finland.jpg)
Growing theranostics program is now everyday clinical practice in Finland
The Comprehensive Cancer Center in Helsinki offers precision therapy personalized to the needs of each patient. Symbia Pro.specta plays a key role in imaging-enabled treatment evaluation.
Intelligent Imaging
Expand your imaging capabilities
Customize your system with dedicated clinical tools that automatically optimize image quality and workflow for cardiology, oncology, neurology, and more.
Technical Details
Bore diameter
70 cm
Tunnel length
106.4 cm
Slices
32/647
Rotation time
up to 0.33 s7
Tube
up to 7.0 MHU7 (17.5 MHU equivalent value with SAFIRE8)
Power
up to 75 kW7 (187 kW equivalent value with SAFIRE8)
High voltage
up to 70-140 kv7 (10kV steps)
mA
up to 825 mA7 (2.06 A equivalent value with SAFIRE8)
Iterative reconstruction
SAFIRE8
Low-dose scanning
Tin Filter
Metal artifact reduction
iMAR5,9
Crystal thickness
3/8” or 5/8”
Detector dimension (FoV)
53.3 x 38.7 cm
Energy range
35-588 keV
System sensitivity (LEHR at 10 cm)
202 cpm/μCi
Acquisition modes
Static, dynamic, gated, SPECT, gated SPECT,
dynamic SPECT, composite SPECT,
whole-body, whole-body SPECT, SPECT/CTQuantitative accuracy
≤ 5%10
Learn more about Symbia Pro.specta