Siemens Healthineers Symbia Intevo Bold SPECT/CT nuclear medicine scanner

Symbia Intevo Bold

Víc CT pro váš SPECT/CT

Symbia Intevo Bold™ kombinuje vysoce výkonné CT s pokročilým SPECT zobrazováním tak, aby systém vyhovoval i nejnáročnějším situacím. Pro ty, kteří chtějí více, nabízí Symbia Intevo Bold příležitost, jak se mohou vaše schopnosti díky řadě jedinečných a výkonných SPECT a CT zdokonalovat.

Features & Benefits

Symbia Intevo Bold
    Man laying on Symbia Intevo Bold scanner bed

    We re-engineered SPECT/CT bone imaging to use CT as the frame-of-reference during image reconstruction. The higher image resolution achieved from xSPECT Bone™ technology enables you to better localize and characterize disease for a more accurate representation of each patient’s condition.

    As patient populations continue to age, the growing presence of metal implants and pacemakers adds complexity to imaging. iMAR, our CT metal-artifact-reduction technique, helps improve both CT and SPECT attenuation correction in these cases.2 xSPECT Bone and iMAR can easily be combined for even greater image clarity.


    Tech positioning female patient on SPECT/CT scanner bed

    For quick and conclusive answers to clinical questions, you need the best image for each patient. However, striking the right balance between image quality and radiation dose can be a challenge, particularly given today’s diverse patient population. Our proprietary CT image reconstruction software and hardware, SAFIRE, lets you accomplish this—quickly and easily.3


    Doctor discussing treatment with patient in front of SPECT scanner

    Adding reliable quantification to your clinical routine can facilitate quicker consensus and generate greater consistency across your institution. Our xSPECT Quant™ and Broad Quantification™ technologies generate highly accurate and reliable measurements to support early diagnoses and optimal therapeutic strategies for a wide array of clinical indications.

    Clinical Use

    Technical Specifications

    Gantry

     

    Tunnel opening

    70 cm

    Tunnel length

    89 cm

    CT

     

    Generator power

    50 kW

    Rotation time

    up to 0.5 s

    Tube voltage

    80, 110, 130 kv

    Iterative reconstruction

    SAFIRE3, 4

    Metal artifact reduction

    iMAR2, 4

    Slices

    16/321

    SPECT

     

    Crystal thickness

    3/8” or 5/8”

    Detector dimension (FOV)

    53.3 x 38.7 cm

    Energy range

    35-588 keV

    System Sensitivity (LEHR at 10 cm)

    202 cpm/μCi

    Acquisition modes

    Static, dynamic, gated, SPECT, gated SPECT, dynamic SPECT, whole-body, whole-body SPECT, SPECT/CT, xSPECT™

    Quantitative accuracy

    ≤ 5%4, 5

    1
    2
    3
    4
    5