SOMATOM Edge PlusChanging views in Computed Tomography
For care providers, the pressure to cut expenses results in an ever-increasing need for standardization and precision medicine. The CT scanner SOMATOM Edge Plus provides diagnostic imaging at the appropriate dose and with reproducible accuracy. Obtain rich, detailed information with technologies that bring tin-filtered scanning, 4D, and quantitative imaging to your clinical routine. And game-changing workflow automation simplifies scan preparation and helps you achieve new levels of precision.
Features & Benefits
Changing views on patient diversity – with personalized scanning
Scan virtually all patients with diagnostic confidence – including obese persons, children, and patients unable to cooperate.
- Get powerful images of obese patients: With SOMATOM Edge Plus, you can obtain sharp and rich-in-contrast images at high speed and low dose even with large patients.
- Gently scan the dose-sensitive ones: Minimize the need for sedation and allow low-dose scans for children with High Power at low kV and integrated CARE Child technology.
- Freeze motion when your patient can't: Excellent image quality within seconds for emergency cases due to the combination of High Power reserves with high coverage of up to 230 mm/s in clinical routine.
Changing views on clinical paradigms – with advanced imaging
Gain new diagnostic insights like functional information and tissue characterization, acquired with no dose or time penalty.
- See more than ever before with tin-filtered scanning: Shield patients from clinically irrelevant dose and use CT for a wider application range with our Tin Filter technology.
- Add dynamic imaging to your clinical routine: Make dynamic imaging an everyday method for nearly all patients and anatomical regions at the right dose and contrast-to-noise ratio.
- Perform advanced quantitative imaging with no dose penalty: Eliminate additional non-contrast scans by creating virtual ones – backed by our unique TwinBeam Dual Energy technology.
Changing views on patient positioning – with automated workflows
Save time and achieve consistent results with smart automation for fast, precise positioning, scanning, and postprocessing.
- Safeguard correct and consistent positioning: Our FAST Integrated Workflow with FAST 3D Camera helps your team acquire first-time right scans and manage tight schedules.
- Get closer to your patients: Set parameters without leaving your patients and offer them individual care with our Touch Panels on eye-level.
- Simplify preparation of patients and scanner: Accelerate workflows and lower dose, helping you optimize process efficiency and improve patient outcome with our software packages.
Clinical Use
4D CTA for follow-up of endovascular repair of an abdominal aortic aneurysm
80 kV
CTDIvol: 35.8 mGy
DLP: 1,035 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- 4D scan range not limited by detector width
- Increase diagnostic certainty with 4D information
Contrast media-enhanced CT for whole-body evaluation of a patient
Scan length: 661 mm
100 kV
CTDIvol: 12.9 mGy
DLP: 819 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- Scanning of even obese patients thanks to wide bore size
- Visualization of tissues even out to 78 cm thanks to HD FoV Pro
- Excellent image quality even in larger patients thanks to the StellarInfinity detector
Single-phase, contrast media-enhanced scan of the abdomen and pelvis for evaluation of multi-cystic disease
Scan length: 535 mm
70 kV
CTDIvol: 8.15 mGy
DLP: 421.56 mGy cm
- Great contrast-to-noise ratio at low dose
thanks to High Power 70
Two-phase, contrast-enhanced staging examination of the abdomen and pelvis
Scan length: 260 mm / 511 mm
90 kV / 90 kV
CTDIvol: 6.87 mGy / 8.25 mGy
DLP: 169.94 mGy cm / 404.08 mGy cm
- Fully diagnostic image thanks to iMAR
Coronary CTA of patient with stable heart rate to rule-out stenosis
Scan length: 104 mm
80 kV
CTDIvol: 5.32 mGy
DLP: 56 mGy cm
HR: 55 bpm (avg.)
- High CNR and potential dose savings thanks to high power at low kV
- Improve reliability of intra-operator image quality thanks to FAST Phase
Contrast media-enhanced CTA of the lower extremities for evaluation of arterial vessel disease
Scan length: 1,349 mm
70 kV
CTDIvol: 1.84 mGy
DLP: 243.69 mGy cm
- High CNR images with potential dose savings thanks to High Power 70
Whole-body CTA of the aorta for assessment of aortic aneurysm
Scan length: 677 mm each
70 kV / 70 kV
CTDIvol: 1.45 mGy
DLP: 94 mGy cm
- High CNR images with potential dose savings thanks to High Power 70
Pediatric ultra-low-dose native lung imaging to assess infiltrates
Scan length: 314 mm
Sn100 kV
CTDIvol: 0.45 mGy
DLP: 12.7 mGy cm
- Lung evaluation at low dose thanks to Tin Filter
Ultra-high-resolution scan of the knee after trauma
Scan length: 171 mm
120 kV
CTDIvol: 34.4 mGy
DLP: 582.43 mGy cm
- Ultra-high resolution thanks to z-Uhr comb
Native follow-up of fracture
Scan length: 238 mm
Sn140 kV
CTDIvol: 19.31 mGy
DLP: 419.09 mGy cm
- Improved beam hardening thanks to Tin Filter
Native low-dose spine imaging for scoliosis evaluation
Scan length: 650 mm
Sn140 kV
CTDIvol: 3.94 mGy
DLP: 294.24 mGy cm
- Tin Filter scan with impressive image quality thanks to beam hardening
Contrast media-enhanced scan of the brain for tumor staging and therapy planning
Scan length: 212 mm
100 kV
CTDIvol: 38.05 mGy
DLP: 731.68 mGy cm
- Excellent image quality thanks to the StellarInfinity detector
Low-dose sinus scan for therapy planning
Scan length: 130 mm
Sn100 kV
CTDIvol: 4.62 mGy
DLP: 50.88 mGy cm
Eff. dose: 0.1 mSv
- Excellent image quality at low dose thanks to Tin Filter
Follow-up of brain bleed after clipping – Volume perfusion
Scan length: 118 mm
70 kV
CTDIvol: 151 mGy
DLP: 1,780 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- Full brain perfusion imaging at low kV thanks to Adaptive 4D Spiral (A4DS)
Follow-up brain scan after shunt implantation
Scan length: 181 mm
110 kV
CTDIvol: 40 mGy
DLP: 646 mGy cm
- 10 kV Steps allowing precise dose selection for each patient
4D CTA for follow-up of endovascular repair of an abdominal aortic aneurysm
80 kV
CTDIvol: 35.8 mGy
DLP: 1,035 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- 4D scan range not limited by detector width
- Increase diagnostic certainty with 4D information
Contrast media-enhanced CT for whole-body evaluation of a patient
Scan length: 661 mm
100 kV
CTDIvol: 12.9 mGy
DLP: 819 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- Scanning of even obese patients thanks to wide bore size
- Visualization of tissues even out to 78 cm thanks to HD FoV Pro
- Excellent image quality even in larger patients thanks to the StellarInfinity detector
Single-phase, contrast media-enhanced scan of the abdomen and pelvis for evaluation of multi-cystic disease
Scan length: 535 mm
70 kV
CTDIvol: 8.15 mGy
DLP: 421.56 mGy cm
- Great contrast-to-noise ratio at low dose
thanks to High Power 70
Two-phase, contrast-enhanced staging examination of the abdomen and pelvis
Scan length: 260 mm / 511 mm
90 kV / 90 kV
CTDIvol: 6.87 mGy / 8.25 mGy
DLP: 169.94 mGy cm / 404.08 mGy cm
- Fully diagnostic image thanks to iMAR
Coronary CTA of patient with stable heart rate to rule-out stenosis
Scan length: 104 mm
80 kV
CTDIvol: 5.32 mGy
DLP: 56 mGy cm
HR: 55 bpm (avg.)
- High CNR and potential dose savings thanks to high power at low kV
- Improve reliability of intra-operator image quality thanks to FAST Phase
Contrast media-enhanced CTA of the lower extremities for evaluation of arterial vessel disease
Scan length: 1,349 mm
70 kV
CTDIvol: 1.84 mGy
DLP: 243.69 mGy cm
- High CNR images with potential dose savings thanks to High Power 70
Whole-body CTA of the aorta for assessment of aortic aneurysm
Scan length: 677 mm each
70 kV / 70 kV
CTDIvol: 1.45 mGy
DLP: 94 mGy cm
- High CNR images with potential dose savings thanks to High Power 70
Pediatric ultra-low-dose native lung imaging to assess infiltrates
Scan length: 314 mm
Sn100 kV
CTDIvol: 0.45 mGy
DLP: 12.7 mGy cm
- Lung evaluation at low dose thanks to Tin Filter
Ultra-high-resolution scan of the knee after trauma
Scan length: 171 mm
120 kV
CTDIvol: 34.4 mGy
DLP: 582.43 mGy cm
- Ultra-high resolution thanks to z-Uhr comb
Native follow-up of fracture
Scan length: 238 mm
Sn140 kV
CTDIvol: 19.31 mGy
DLP: 419.09 mGy cm
- Improved beam hardening thanks to Tin Filter
Native low-dose spine imaging for scoliosis evaluation
Scan length: 650 mm
Sn140 kV
CTDIvol: 3.94 mGy
DLP: 294.24 mGy cm
- Tin Filter scan with impressive image quality thanks to beam hardening
Contrast media-enhanced scan of the brain for tumor staging and therapy planning
Scan length: 212 mm
100 kV
CTDIvol: 38.05 mGy
DLP: 731.68 mGy cm
- Excellent image quality thanks to the StellarInfinity detector
Low-dose sinus scan for therapy planning
Scan length: 130 mm
Sn100 kV
CTDIvol: 4.62 mGy
DLP: 50.88 mGy cm
Eff. dose: 0.1 mSv
- Excellent image quality at low dose thanks to Tin Filter
Follow-up of brain bleed after clipping – Volume perfusion
Scan length: 118 mm
70 kV
CTDIvol: 151 mGy
DLP: 1,780 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- Full brain perfusion imaging at low kV thanks to Adaptive 4D Spiral (A4DS)
Follow-up brain scan after shunt implantation
Scan length: 181 mm
110 kV
CTDIvol: 40 mGy
DLP: 646 mGy cm
- 10 kV Steps allowing precise dose selection for each patient
4D CTA for follow-up of endovascular repair of an abdominal aortic aneurysm
80 kV
CTDIvol: 35.8 mGy
DLP: 1,035 mGy cm
- High CNR and potential dose savings thanks to high power at low kV
- 4D scan range not limited by detector width
- Increase diagnostic certainty with 4D information
Technical Specifications
Detector: | StellarInfinity detector |
Number of acquired slices: | 128 |
Number of reconstructed slices: | 384 |
Spatial resolution: | 0.30 mm |
Rotation time: | 0.28 s |
In-plane temporal resolution: | 142 ms |
Generator power: | 100 kW |
kV steps: | 70, 80, 90, 100, 110, 120, 130, 140 kV |
Max. scan speed: | 23 cm/s |
Table load: | up to 307 kg / 676 lbs |
Gantry opening: | 78 cm |