MAGNETOM Vida

MAGNETOM VidaEmbrace human nature at 3T

MAGNETOM Vida
Discover how to embrace human nature at 3T.

MAGNETOM Vida – the first 3T MRI scanner with BioMatrix Technology – embraces human nature and the unique set of challenges that each patient brings to the MRI exam. By embracing these challenges, we overcome patient variability – ushering in a paradigm shift in MRI. The outcome: fewer rescans, predictable scheduling and consistent, high-quality personalized exams for high-end clinical routine as well as clinical research.

Features & Benefits

MAGNETOM VidaGradient powerUltra-high density 3T coilsTurbo SuiteFree-breathing applicationsBioMatrix dockable table with eDriveBioMatrix Select&GOBioMatrix TunersBioMatrix SensorsEco-PowerMR Fingerprinting

    Siemens - MRI - 3T MRI Scanners - MAGNETOM Vida - Embrace full 3T performance with unparalleled magnet and gradient power

    3T MRI is synonymous with high-performance clinical MRI. With 3T MRI, the expectation is to push and redefine the limits of what is possible in diagnostic imaging.

    An all-new 3T magnet

    MAGNETOM Vida comes with an all-new 3T magnet, which provides excellent homogeneity throughout the entire measurement volume and a large Field-of-View of 55 x 55 x 50 cm3. The result: fast examinations with robust and reliable fat saturation throughout the entire imaging volume, which is especially important in abdominal or off-center applications.

    A new level of gradient power

    With a gradient strength of up to 60/200 simultaneously for up to 25% higher SNR in diffusion weighted imaging, MAGNETOM Vida offers MR research power – but now in a patient-friendly 70 cm setting.

    Cost-efficient energy management

    An intelligent power management disables power-consuming components during scan breaks – EcoPower shuts off the cold head in standby, resulting in up to 30% energy savings compared to the industry average (COCIR average of MRI vendors3,4).


    MAGNETOM Vida embraces true 3T productivity and makes fast scan times and push-button examinations become clinical reality. At the core of its impressive acquisition speed lies our exclusive Turbo Suite: Disruptive acceleration technologies (e.g. Simultaneaous Multi-Slice and Compressed Sensing) shortening the entire examinations for the whole spectrum of clinical MRI, while keeping the quality of exam results.

    GO Technologies are a family of solutions that accelerates the entire workflow of the examination: from patient positioning to result distribution.

    GO Technologies consist of four main components, each contributing to a specific aspect of workflow optimization to enable higher throughput and robustness in clinical routine.


    Siemens - MRI - 3T MRI Scanners - MAGNETOM Vida - Embrace new 3T clinical capabilities with Inline Compressed Sensing

    With Turbo Suite Elite, MAGNETOM Vida provides access to patients previously excluded from MRI because of their medical condition or the exam’s prohibitively complicated nature. Compressed Sensing Cardiac Cine and Compressed Sensing GRASP-VIBE enable free-breathing exams which help improve the patient experience, while extending your range of services. Significantly simplified procedures with automated workflow strengthen clinical fields with growth potential such as whole-body MRI.

    With MR Fingerprinting (MRF)5, MAGNETOM Vida enables diagnostics at the frontier of a paradigm shift. MRF uses quantitative information from scans for decisions based on digital tissue data, not visual impressions, to improve tissue differentiation and enable less invasive diagnostics.

    Clinical Use

    See the consistent high-quality perzonalized exams of MAGNETOM Vida and our BioMatrix technology.

    See the full application range in the MAGNETOM Vida Image Gallery.



    Preview_Clinical_acceleration_from_the_console.

    Read how Benson Radiology (North Adelaide, Australia) with their new MAGNETOM Vida speed up imaging without compromising on image quality and spatial resolution.

     

    Find more MAGNETOM Vida specific clinical talks and case studies on MAGNETOM World, the Siemens MR user community forum.

    Technical Details

    Magnet System

     

    Field strength

    3 Tesla

    Bore size

    70 cm / 2.30 ft Open Bore design

    Helium consumption

    Zero Helium boil-off technology

    Shimming

    Passive and active

     

     

    Gradient strength

    XQ gradients 45/200 simultaneously [2.03 MW]
    XT gradients 60/200 simultaneously [2.70 MW]

     

     

    Power consumption

    Eco-Power technology

     

     

    Siting and Installation

     

    System length

    186 cm / 6.10 ft cover to cover

    System weight (in operation)

    7.35 tons / 15,432.36 lb

    Minimum room size7

    31 m2 / 333.68 sq ft

    1
    2
    3
    4
    5
    6
    7