Neurodegenerative Diseases

Alzheimer's disease therapy monitoring with MRI

50 Million people suffer from Alzheimer’s disease (AD) worldwide. 1.6 Million people die from AD every year, making AD the second leading cause for death in Neurology worldwide.1

Until now it has no cure, but recently, drugs that can slow the progress of Mild Cognitive Impairment (MCI) – the early stage of Alzheimer’s Disease (AD) – have become available. Possible side effects of these drugs are called Amyloid Related Imaging Abnormalities (ARIA), and MRI is the method of choice to monitor these for the occurrence of ARIA.

In July 2023, the US Food and Drug Administration (FDA) for the first time gave traditional approval to amyloid beta directed antibody for the treatment of AD. With such Disease Modifying Therapies (DMTs) entering the clinic, the potential to improve patient care and possibly slow disease progression is enormous.

How a Disease Modifying Therapy works

This family of treatments target the pathology of Alzheimer's disease by reducing the amyloid beta plaques that typically accumulate in the brains of AD patients. Clinical studies have demonstrated that removing amyloid beta from brain reduces cognitive and functional decline in patients living with early AD2,3

Amyloid beta protein accumulates around brain neurons in Alzheimer’s
Amyloid beta protein accumulates around brain neurons in Alzheimer’s
DMT antibody binds to amyloid beta protein
DMT antibody binds to amyloid beta protein
Antibody attracts immune cells to break down the protein
Antibody attracts immune cells to break down the protein
Less amyloid beta protein around the neuron
Less amyloid beta protein around the neuron

MRI is the diagnostic tool of choice for detecting ARIA and regular MR scans are recommended for patients undergoing monoclonal antibody-based therapy. ASNR recommends using T2 FLAIR for monitoring of ARIA-E and T2* gradient-echo imaging for detection of ARIA-H.4 Additionally, in case of stroke like symptoms, DWI helps to determine if the root cause is ischemia or ARIA. FDA recommends MRI monitoring scans for Leqembi5 and Kisunla6 according to the following schedules.

Requirements for therapy monitoring by FDA

For Leqembi

For Kisunla

ASNR kindly prepared together with our collaborators from Washington University, St. Louis/MO, USA, the required protocols for MAGNETOM scanners. All Siemens Healthineers MAGNETOM MRI scanners are capable of providing the required T2 FLAIR, T2*, and DWI contrasts.

1
2
3
4
5
6
Subscription Button Icon

Keep up to date on the latest trends in healthcare. Read about current developments, new products and upcoming events.