Stress-rest relative perfusion PET shows decreased but reversible perfusion in anterior wall, septum, and apex. Inferior wall shows moderate reversible perfusion abnormality

Delineation of multivessel coronary artery disease and post-therapy stent occlusion with 82Rb myocardial perfusion PET/CT and blood flow estimation

2022-08-17


By Parthiban Arumugam, MD and Yahya Al-Najjar, MD, Manchester Royal Infirmary, Manchester, United Kingdom
Data and images courtesy of Manchester Royal Infirmary, Manchester, United Kingdom

A 62-year-old female presented with atypical chest pain and a history of major risk factors for coronary artery disease (CAD), including obesity (high body mass index, height of 168 cm [5’5”], and a weight of 103 kg [227 lb]), hypertension, diabetes, hyperlipidemia, and a family history of CAD. 

The patient underwent a Rubidium 82 (82Rb) PET/CT myocardial perfusion study on a Biograph VisionTM PET/CT system. The initial dynamic acquisition at rest was performed following 82Rb infusion. Following adenosine stress infusion, the patient received a 20 mCi (740 MBq) intravenous (IV) injection of 82Rb followed immediately with a 5-minute dynamic list-mode acquisition.

A low-dose CT was acquired prior to the rest image acquisition for attenuation correction (AC).

As seen in Figure 1, the perfusion study reflects severe multivessel CAD with significant stress-induced left ventricular (LV) cavity dilation. There is severe reduction in tracer uptake  at the apex and all peri-apical segments along with a mild reduction to the mid/basal inferior myocardium at peak stress. The tracer uptake at rest is within normal limits reflecting a large area of stress-inducible ischemia in the left anterior descending (LAD) territory as well as moderate ischemia in the right coronary artery (RCA) territory.

The gated PET study seen in Figure 2 demonstrates a dyskinetic septum along with a hypokinetic apex and adjoining periapical segments at peak stress. The left ventricle appears dilated with an ejection fraction of 60%. There is no regional wall motion abnormality at rest with an ejection fraction of 74%. Such severe post-stress dilatation and decrease in the left ventricular ejection fraction at peak stress reflects advanced multivessel CAD.

The myocardial blood flow (MBF) assessment using dynamic list-mode data performed on syngo®.via (Figure 3) shows decreased stress MBF in LAD and RCA territories with low myocardial blood flow reserve (MBFR) of 1.9 and 1.6, reflecting severe ischemia with normal resting blood flow. The left circumflex (LCX) territory shows normal stress blood flow value and normal MBFR. In view of the presence of hypertension and high resting heart rate, the MBF values were normalized to the resting heart rate of 97 beats per minute (BPM) and resting systolic blood pressure of 149 mm Hg. Polar plots of the MBF and MBFR reveal severe ischemia in the apex and peri-apical anterior wall and septum.

Evaluation of the extent of stress perfusion defect and blood flow abnormalities was consistent with multivessel pattern of ischemia and evidence of post-ischemic stunning. Significant stress-inducible ischemia involved at least 10/20 myocardial segments with a predominant LAD distribution. Normal resting LV systolic function and uniform normal resting perfusion reflects the complete reversibility of the stress-induced perfusion defects.

The patient subsequently underwent coronary angiography. 

Coronary angiography revealed severe stenosis in mid-LAD and proximal-RCA. Both lesions were subsequently treated with balloon angioplasty and stent insertion. Post-percutaneous coronary intervention (PCI) images (Figure 5) show restoration of normal vascular flow in the LAD and RCA.

As evident in Figure 6, coronary angiography demonstrated luminal irregularities in the mid-LCX artery which was identified as residual disease but not deemed severe enough for intervention with adequate contrast flow to the distal-LCX, obtuse margin 1 (OM1), and obtuse margin 2 (OM2).

Immediately following the PCI, the patient was re-admitted with hypoxemic (Type 1) respiratory failure. Lung perfusion SPECT/CT was negative for pulmonary embolism, and the serum troponin was also negative. The patient recovered following ventilatory support. However, there was another subsequent admission 6 months post-PCI with chest pain and respiratory distress. In the second instance, the serum troponin was also negative.

Due to repeated chest pain, a repeat PET/CT myocardial perfusion study was requested. The 82Rb myocardial perfusion PET/CT study was performed on the Biograph Vision system with acquisition parameters similar to the initial study. 

There is mild stress-induced LV cavity dilatation which reflects severe ischemia. However, the resting LV cavity size is normal.

As evident in the post-PCI PET/CT myocardial perfusion study (Figures 7-9), there is functionally significant ischemia in the inferior wall and inferoseptal segment while the LAD and LCX territory shows normal stress perfusion. When compared to the previous study, there is complete resolution of LAD ischemia. However, the presence of a large perfusion defect in the inferior and inferoseptal segments suggests a new significant ischemia in the posterior descending artery (PDA) distribution (6/20 segments). LV systolic function is normal reflecting the moderate degree of ischemia at peak stress.

The patient then underwent a follow-up coronary angiography. 

Coronary angiography revealed complete occlusion of the RCA stent along with significant flow impairment related to the luminal irregularity in the distal-LCX, which together contribute to the reversible ischemia in the inferior wall and inferoseptal region. The lateral and postero-basal walls are normally perfused since the proximal and mid-LCX show normal luminal flow. The distal LCX irregular luminal lesion with reduced FFR of 0.6 contributes to the inferior wall ischemia while the completely occluded RCA contributes to the inferoseptal as well as the inferior wall ischemia.

In view of the coronary angiography results, the patient underwent drug-eluting balloon angioplasty of both the RCA and distal LCX. Normal distal flow was restored in both vascular territories following the angioplasty.

This clinical case example illustrates the value of 82Rb PET/CT myocardial perfusion imaging with MBF estimation in detecting multivessel CAD and guiding therapeutic intervention as well as detecting restenosis on follow-up. The severity of the stress-induced perfusion defect in the initial study along with the reduction in absolute value of stress MBF in the affected LAD and RCA territories compared to the normal LCX territory reflects the image quality and quantification advantage of myocardial perfusion PET/CT, especially with current-generation silicon photomultiplier (SiPM) systems like Biograph Vision with excellent time-of-flight (ToF) performance, high count-rate capability, and low detector saturation.

The average LAD territory MBF was 1.84 ml/gm/min at peak stress while that of the normally perfused LCX territory was 2.95 ml/gm/min, although the resting blood flow in both territories was similar. This difference in stress MBF of nearly 40% between ischemic and normally perfused myocardium reflects the quantitative accuracy of PET blood flow estimation. Stress-induced LV dilatation and wall-motion abnormalities evident on static and gated stress PET images reflect multivessel disease while normal resting myocardial perfusion and left ventricular ejection fraction (LVEF) confirm the complete reversibility of the ischemic segments. The stress MBF in the inferior wall (RCA territory) shows further reduction compared to the LAD territory with a stress MBF value of 1.17 ml/gm/min, which reflects the severity of the hemodynamic impairment due to the RCA stenosis as compared to that of the LAD. Even resting perfusion in the RCA territory is significantly lower compared to that of the LAD, although it is within the normal range. Although MBF is impacted by multiple factors over and above stenosis severity, including the state of collateral circulation and microvascular disease, studies have shown a correlation between absolute MBF and coronary flow reserve (CFR) with stenosis severity.

In a study performing 82Rb dynamic PET for MBF estimation compared with stenosis estimation by quantitative coronary angiography, 15 patients with angiographically documented CAD and 7 age-matched asymptomatic controls without CAD risk factors were studied. Rest and stress MBF in regions subtended by vessels with < 50% stenosis was similar to that of the individuals without risk factors for CAD. MBFR was similar in the two groups (average 1.9 compared to 2.2). MBFR values were able to differentiate coronary lesions with 70% to 89% stenosis from those with 50% to 69% stenosis (average MBFR of 1 compared to 1.7 for the group with lower stenosis levels). MBF at peak stress and MBFR were inversely correlated to the percent diameter stenosis on angiography. The absolute MBF and MBFR values in the ischemic segments in the present study are comparable to that of published studies.1

In-stent restenosis is an established complication following coronary stenting, although the incidence is less than 10% for drug-eluting stents.2 As in this case example, restenosis can precipitate acute ischemic episodes, including hypoxemic respiratory failure. The follow-up 82Rb PET/CT myocardial perfusion study clearly demonstrates the reversible perfusion defect in inferior and inferoseptal wall, which reflected involvement of the RCA territory, more specifically the PDA distribution. The RCA territory average MBF was 1.65 ml/gm/min at peak stress, which was significantly higher than the value in the initial study. The resting RCA MBF was also higher at 0.90 ml/gm/min. The coronary angiography confirmed in-stent restenosis of the RCA along with identification of the distal LCX luminal irregularities as hemo-dynamically significant due to the reduced FFR of 0.6. Both of the lesions contributing to the inferior wall and inferoseptal ischemia were treated with drug-eluting balloon angioplasty, which has been shown to have a lower incidence of restenosis. The normal stress and resting LVEF, absence of stress-induced wall-motion abnormalities, and normal resting perfusion reflect the moderate nature of the ischemia and the complete reversibility of the ischemic myocardium.

A 82Rb stress-rest PET/CT myocardial perfusion study with absolute quantification of MBF is an accurate technique for detection and characterization of myocardial ischemia in order to guide therapy as well as a follow-up procedure to detect post-PCI complications such as in-stent restenosis, stenosis progression, or development of fresh coronary stenosis. Absolute values of stress MBF, MBFR, and post-stress LV cavity dimensions also contribute to the assessment of disease severity and reversibility of ischemic segments.

Scanner: Biograph Vision

PET

 

Injected dose

20 mCi (740 MBq) 82Rb

Post-injection delay

Immediate post-injection dynamic list-mode acquisition

Acquisition

5-minute dynamic list-mode acquisition

Scan time

5-minute dynamic rest and stress acquisition

Subscription Button Icon

Keep up to date on the latest trends in healthcare. Read about current developments, new products and upcoming events.