RAPIDLab 1200 SystemsPerfect choice for medium to high workload environments

Designed to maximize turnaround time, RAPIDLab® 1200 Systems have the capacity to enhance blood gas testing efficiency in the clinical laboratory by combining testing speed and reliability with low maintenance. RAPIDLab 1200 systems are our proven solution for high-volume critical care testing sites.

Leverage the benefits of RAPIDLab 1200 Systems:

  • Comprehensive test menu addresses a variety of critical care testing needs
  • Intuitive operation and minimal maintenance help increase productivity without increasing staff.
  • Industry-proven accuracy and reliability through long-life Ready Sensor® electrode technology
  • Biosafe automatic sampling system with clot detection and clearance
  • Effortless onboard Automatic Quality Control (AQC) for enhanced quality assurance and regulatory compliance

    Features & Benefits

    Designed to meet the challenges of the busy clinical lab or various hospital settings, RAPIDLab® 1200 Systems address all your critical care testing needs:

    • Extensive test menu includes full CO-oximetry and neonatal total bilirubin
    • Ready Sensor® electrode technology for industry-proven reliability
    • Cost-effective, cartridge-based system
    • Simplified operation with biosafe sampling
    • Automatic quality control and documentation
    • Seamless integration with your LIS/HIS
    • Dedicated technical support and on-site service

    RAPIDLab 1200 Systems' testing performance, accuracy and consistency make it an excellent choice as your NICU monitoring solution:

    • Ultra-fast sample processing enables immediate physician intervention
    • Clinical accuracy reduces the need to repeat tests
    • Microsample capability enables testing of very small sample volumes without compromising accuracy
    • Full test menu from a single sample

    When it comes to such small and vulnerable patients, fast results, delivered instantly, can make a big difference.

    • RAPIDLab 1200 Systems parameter listing:

    Blood Gas (pH, pCO2, pO2)

    Electrolytes (Na+, K+, Ca++, Cl- )

    Metabolites (Glucose, Lactate, Neonatal Total Bilirubin)

    CO-oximetry (tHb, HHb, O2Hb, sO2, COHb, MetHb)

    • Testing panels can be customized to meet specific needs
    • Capable of running the full test menu on short-sample patient draws (microsamples)
    • Intuitive touchscreen and automatic single sample port (syringe and capillary) speed up the testing process
    • All reagents are contained in sealed cartridges for enhanced operator safety and low maintenance
    • Clot detection and clearance with biosafe automatic sampling system
    • Onboard automatic quality control cartridge requires no operator intervention during the 28-day use life
    • The entire sample pathway is analyzed at an operator-definable frequency
    • Long-life Ready Sensor® electrodes ensure industry-proven accuracy and reliability
    Achieve maximum control and connectivity
    • Seamless integration with our RAPIDComm® Data Management System or third-party vendor connectivity solutions
    • Laboratory managers/supervisors have direct access to monitor and control all Siemens critical care systems on the hospital network
    • Instant clinician access to patient results from networked POC analyzers
    • Dual LIS transmission support enables both the serial port and the ethernet port to communicate simultaneously

    Assays

    Parameters*

    Analyte

    Blood Gas

    pH
    pCO2
    pO2

    Electrolytes

    Na+
    K+
    Ca++
    CI-

    Metabolites

    Glucose
    Lactate

    CO-oximetry

    tHb
    HHb
    O2Hb
    sO2
    COHb
    MetHb

    Neonatal Total Bilirubin

    Technical Specifications

    Sample Size: Syringe (1 mL)/Capillary (Minimum)
    RAPIDLab 1240
    RAPIDLab 1245
    RAPIDLab 1260
    RAPIDLab 1265
    pH Only
    35 µl
    35 µl
    95 µl
    95 µl
    CO-oximetry Only
    --
    100 µl
    --
    100 µl
    Full Menu
    90 µl
    140 µl
    125 µl
    175 µl

     

     

     

     

    Analysis

    Time to Results:
    60 seconds

    Cartridges

    Reagent Cartridge Use Life:

    30 days

    Wash Cartridge Use Life:

    Sample dependent

    AQC Cartridge Use Life:
    28 days

    Calibration

    1 point Calibration
    Every 30 minutes
    Full Cal Calibration
    Every 8 hours

    Environmental

    Temperature:

    15°C-32°C

     

     

    Humidity:

    5%-85% non-condensing

    System Dimensions

    Width:

    58.4 cm (23.0 in.)

    Height:

    57.2 cm (22.5 in.)

    Depth:

    55.9 cm (22 in.)

    Weight:

    29.5 kg (65 lb)

    Power Requirement

    Rating:

    150VA

    Voltage:

    100-240V

    Frequency:

    50/60Hz

    External Interfaces

    USB Printer Port, RS232 Port, Bar Code Scanner Port, RJ10/100 Base T Ethernet Port

    Approvals

    EN 60601-1-2:2001, Group 1, Class B, CB Test Certificate, UL Certificate, CSA Certified

    Subscription Button Icon
    Be the first to know about our events, training, and news