The SOMATOM go. platform with myExam Companion Made to match: CT scanners designed to meet your needs
Clinical trends and guidelines change. Your needs evolve. Our solutions evolve. From routine to advanced procedures, the new SOMATOM® go. platform offers the right CT scanner for your clinical tasks. Each scanner features innovations that make it smarter and even more patient-centric:
- The latest AI-supported workflows to support your staff
- Expanded clinical capabilities to meet the needs of your patients
- Seamless integration in our products and services to match your goals
Smart – intelligent tools to match your workflows
Amid ongoing radiology workforce shortages, the demands on staff continue to rise. To support users in their daily work and help them meet radiologists’ expectations, the SOMATOM go. platform features myExam Companion, providing AI-supported guidance to patients and operators throughout the workflow and driving consistency in exam setup and image quality.
Unleash the full potential of your CT scanner with customizable protocols and automated support from patient preparation through data distribution. Intelligent guidance works with users to reduce workloads. It makes advanced procedures routine and helps generate consistent, standardized results at ALARA dose.
- myExam Compass – individualization based on real-time patient data and user input
- myExam Cockpit – customize your clinical protocol to personalize myExam Compass
- FAST 3D Camera gantry-mounted1 – patient positioning powered by AI
- GO technologies – AI-based user guidance
Put patients at ease and improve their experience with the next level of mobile workflow. AI-supported automation increases standardization and achieves significant dose reductions for a broad variety of patient characteristics.
- Mobile workflow – the freedom to work wherever works best
- myExam Care – put patients’ well-being in the center
- CARE Breathe1– intuitive color-coded guidance for breath-hold
- CARE Moodlight1 – integrated ambient lighting and smart visual guidance
- CARE 2D Camera – monitor patients’ well-being throughout the procedure
Flexible – performance to match your clinical needs
As CT becomes increasingly relevant, many healthcare facilities are expected to handle a broad variety of complex and specialized procedures. The SOMATOM go. platform of CT scanners helps you tackle your specific clinical setup and tasks so you can optimally adapt to each patient and produce consistent results for a diverse patient mix.
Powerful components deliver standardized images in unprecedented quality for CT scanners of the SOMATOM go. platform. AI-supported workflows ensure the whole imaging chain operates in perfect harmony. From the X-ray tube to the detector, it is optimized for image quality and dose.
Powerful hardware and the latest software help maintain throughput and enhance image quality in challenging cases.
- ZeeFree12 – a scanner integrated reconstruction feature which reduces the stack misalignments. This feature is independent from the physical detector width of the acquired data.
- The Chronon® X-ray tube offers up to 400 mA at low kV and delivers 0.5s rotation time allowing for shorter breath-holds on the SOMATOM go.Up. The Athlon® X-ray tube offers up to 825 mA at low kV with a rotation speed of up to .33s.
Productive – a smart investment to match your goals
When purchasing a CT scanner, there is more than just the equipment cost to consider. With the SOMATOM go. platform, you benefit from reduced lifecycle costs, new reimbursement opportunities, and a connected fleet.
Reduce costs with our flexible one-room concept, energy savings, and the gantry-integrated 3D camera.
- Flexible one-room concept – with a scanner footprint7 of just 4 m2
- FAST 3D Camera gantry-mounted1 – no need for additional ceiling infrastructure
- Lifecycle costs – improved CT energy efficiency through reduced power consumption
Keep your systems running smoothly, avoid unplanned downtime, and manage your Siemens Healthineers CT scanner fleet 24/7 from any browser-capable device.
- Advance Plans – solutions for optimum service and future-readiness
- teamplay Protocols – share protocols across your CT fleet
- Hybrid learning – personalize learning tools to boost staff competence
Unlock wider patient reach with the evolved SOMATOM go. platform and get access to additional reimbursement opportunities:
- CT-guided intervention1
- Cardiac CT1
- Lung cancer screening1
- Spectral imaging1
Meet the platform
SOMATOM go.Up
Designed for daily routine to help you adhere to clinical guidelines. Handle throughput and challenging cases with ease.
SOMATOM go.All
Unlock more than routine – covering daily procedures and ready for more advanced ones when needed.
SOMATOM go.Top
A versatile scanner for full flexibility to handle all routine procedures and the most important advanced ones to cater to a wider range of patients.
Clinical case gallery
Peripheral run-off CT angiography
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 28 s
Scan length: 1198 mm u
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 110 kV
CTDIvol: 4.48 mGy
DLP: 526 mGy cm
- Fine visualization of peripheral vessels
- Automatic Recon&GO inline results
Brain imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Brain imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s u
Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Adding Tin Filter technology to your clinical daily rotuine low dose lung protocol
SOMATOM go.Up
Scan time: 9 s
Scan length: 33 cm
Pitch: 0.8
Rotion time: 0.5 s
Sn110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- Profit from high density of detector channels
- High image quality combined with optimized radiation dose with Tin filter
Combining high pitch and fast rotation time for high resolution lung Imaging
SOMATOM go.Up
Scan time: 6 s
Scan length: 32 cm
Pitch: 1.2
Rotion time: 0.5 s
110 kV
CTDIvol: 3.46 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- High image quality with perfectly attuned imaging chain and SAFIRE reconstructions
Pulmonary embolism evaluation in emmergency setting
SOMATOM go.Up
Scan time: 7 s
Scan length: 38 cm
Pitch: 1.15
Rotion time: 0.5 s
110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- High pitch and fast rotation for optimizing scan time
- Delivering excellent image quality in daily clinical relevance
Two-step thorax and abdomen imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax) 21 s (abdomen)
Scan length: 392 mm (thorax) 502 mm (abdomen)
Rotation time: 0.8 s (each)
Pitch factor: 0.8 (each)
Scan parameters: 130 kV / 58 mAs (thorax); 130 kV / 98 mAs (abdomen)
CTDIvol: 5.37 mGy (thorax) 10.5 mGy (abdomen)
DLP: 197 mGy cm (thorax) 502 mGy cm (abdomen)
- Follow-up after partial liver resection
- Multi-step CT protocol
Two-step thorax and abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax)
Scan length: 392 mm (thorax)
Rotation time: 0.8 s
Pitch factor: 0.8
Scan parameters: 130 kV / 58 mAs (thorax)
CTDIvol: 5.37 mGy (thorax)
DLP: 197 mGy cm (thorax)
- VRT based on thoracic spiral
- Confirm correct organ coverage and contrast agent distribution with Check&GO
Peripheral run-off CT angiography
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 28 s
Scan length: 1198 mm u
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 110 kV
CTDIvol: 4.48 mGy
DLP: 526 mGy cm
- Fine visualization of peripheral vessels
- Automatic Recon&GO inline results
Brain imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Brain imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 15 s
Scan length: 214 mm
Rotation time: 1 s u
Pitch factor: 0.55
Scan parameters: 130 kV / 104 mAs
CTDIvol: 41.2 mGy
DLP: 779 mGy cm
- Visualization of aneurysm
Adding Tin Filter technology to your clinical daily rotuine low dose lung protocol
SOMATOM go.Up
Scan time: 9 s
Scan length: 33 cm
Pitch: 0.8
Rotion time: 0.5 s
Sn110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- Profit from high density of detector channels
- High image quality combined with optimized radiation dose with Tin filter
Combining high pitch and fast rotation time for high resolution lung Imaging
SOMATOM go.Up
Scan time: 6 s
Scan length: 32 cm
Pitch: 1.2
Rotion time: 0.5 s
110 kV
CTDIvol: 3.46 mGy
Image type: 0.8 mm Br40 | Bl64
- 0.8 mm slice reconstruction
- High image quality with perfectly attuned imaging chain and SAFIRE reconstructions
Pulmonary embolism evaluation in emmergency setting
SOMATOM go.Up
Scan time: 7 s
Scan length: 38 cm
Pitch: 1.15
Rotion time: 0.5 s
110 kV
CTDIvol: 1.67 mGy
Image type: 0.8 mm Br40 | Bl64
- High pitch and fast rotation for optimizing scan time
- Delivering excellent image quality in daily clinical relevance
Two-step thorax and abdomen imaging with i.v. contrast media application 1/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax) 21 s (abdomen)
Scan length: 392 mm (thorax) 502 mm (abdomen)
Rotation time: 0.8 s (each)
Pitch factor: 0.8 (each)
Scan parameters: 130 kV / 58 mAs (thorax); 130 kV / 98 mAs (abdomen)
CTDIvol: 5.37 mGy (thorax) 10.5 mGy (abdomen)
DLP: 197 mGy cm (thorax) 502 mGy cm (abdomen)
- Follow-up after partial liver resection
- Multi-step CT protocol
Two-step thorax and abdomen imaging with i.v. contrast media application 2/2
SOMATOM go.Up
Collimation: 32 x 0.7 mm (each)
Scan time: 16 s (thorax)
Scan length: 392 mm (thorax)
Rotation time: 0.8 s
Pitch factor: 0.8
Scan parameters: 130 kV / 58 mAs (thorax)
CTDIvol: 5.37 mGy (thorax)
DLP: 197 mGy cm (thorax)
- VRT based on thoracic spiral
- Confirm correct organ coverage and contrast agent distribution with Check&GO
Peripheral run-off CT angiography
SOMATOM go.Up
Collimation: 32 x 0.7 mm
Scan time: 28 s
Scan length: 1198 mm u
Rotation time: 0.8 s
Pitch factor: 1.5
Scan parameters: 110 kV
CTDIvol: 4.48 mGy
DLP: 526 mGy cm
- Fine visualization of peripheral vessels
- Automatic Recon&GO inline results
Evaluation of coronaries in a high risk patient ECG-gated spiral 3/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- Automated, zero-click reconstruction of CPRs
Rule-out of bleeding and vascular status clarification
Non-contrast and contrast-enhanced brain CTA scan
SOMATOM go.All
Scan time: 13 / 2 s
Scan length: 185 / 192 mm 120 / 80 kV
CTDIvol: 38.4 / 6.3 mGy
DLP: 603 / 103 mGy cm
- Optimal low-contrast performance for differentiation of gray/white matter
- Powerful low-kV imaging
Evaluation of severe peripheral vessel disease Run-off CTA after bypass surgery
SOMATOM go.All
Scan time: 30 s
Scan length: 1223 mm 80 kV
CTDIvol: 3.16 mGy
DLP: 399 mGy cm
- Contrast enhancement even in distal vasculartue with 80kV
Evaluation of trunk to rule-out pathologies Single phase contrast-media-enhanced scan
SOMATOM go.All
Scan time: 17 s
Scan length: 614 mm 110 kV
CTDIvol: 6.14 mGy
DLP: 281 mGy cm
- Ease all your CT demands with flexible kV settings and automated reconstruction
- Optimal results thanks to Stellar detector
Evaluation of coronaries in a high risk patient ECG-gated spiral 1/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- 165 ms temporal resolution for great acquisition and visualization of the heart and its coronary arteries
Evaluation of coronaries in a high risk patient ECG-gated spiral 2/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm
110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- CARE kV in combination with the 10 kV steps and automated Best Phase detection
Evaluation of coronaries in a high risk patient ECG-gated spiral 3/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- Automated, zero-click reconstruction of CPRs
Rule-out of bleeding and vascular status clarification
Non-contrast and contrast-enhanced brain CTA scan
SOMATOM go.All
Scan time: 13 / 2 s
Scan length: 185 / 192 mm 120 / 80 kV
CTDIvol: 38.4 / 6.3 mGy
DLP: 603 / 103 mGy cm
- Optimal low-contrast performance for differentiation of gray/white matter
- Powerful low-kV imaging
Evaluation of severe peripheral vessel disease Run-off CTA after bypass surgery
SOMATOM go.All
Scan time: 30 s
Scan length: 1223 mm 80 kV
CTDIvol: 3.16 mGy
DLP: 399 mGy cm
- Contrast enhancement even in distal vasculartue with 80kV
Evaluation of trunk to rule-out pathologies Single phase contrast-media-enhanced scan
SOMATOM go.All
Scan time: 17 s
Scan length: 614 mm 110 kV
CTDIvol: 6.14 mGy
DLP: 281 mGy cm
- Ease all your CT demands with flexible kV settings and automated reconstruction
- Optimal results thanks to Stellar detector
Evaluation of coronaries in a high risk patient ECG-gated spiral 1/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- 165 ms temporal resolution for great acquisition and visualization of the heart and its coronary arteries
Evaluation of coronaries in a high risk patient ECG-gated spiral 2/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm
110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- CARE kV in combination with the 10 kV steps and automated Best Phase detection
Evaluation of coronaries in a high risk patient ECG-gated spiral 3/3
SOMATOM go.All
Scan time: 8.2 s
Scan length: 144 mm 110 kV
CTDIvol: 10.38 mGy
DLP: 180 mGy cm
Heart Rate: 59 bpm
- Automated, zero-click reconstruction of CPRs
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 3/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Automated results
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 1/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- CARE kV combined with 10 kV Steps
- Automated, zero-click reconstruction of CPRs
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 2/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- Optimal image quality due to CARE kV in 10 kV Steps
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Evaluation of vascular territories Flex 4D Spiral scan
SOMATOM go.Top
Scan time: 41.8 s
Scan length: 58 mm 70 kV
CTDIvol: 145.8 mGy
DLP: 1604 mGy cm
- Flexible handling of 4D perfusion scans thanks to Flex 4D Spiral
- 70 kV for improved contrast to noise ratio
- Achieve a scan range of up to 8.4 cm with cycle time of 1.5 s
Trauma patient Native whole-body evaluation
SOMATOM go.Top
Scan time: 21 s
Scan length: 1875 mm 120 kV
CTDIvol: 6.08 mGy
DLP: 1175 mGy cm
- High resolution throughout the long scan range thanks to Stellar detector and powerful Athlon tube
- Automated result creation with Recon&GO
Evaluation of pancreatic mass Multi-phase including TwinBeam Dual Energy abdomen CT scan
SOMATOM go.Top
Scan time: 3 / 2 / 14 s
Scan length: 265 / 232 / 518 mm
110 / 130 / AuSn120 kV
CTDIvol: 6.7 / 7 / 6.1 mGy
DLP: 181 / 165 / 292 mGy cm
- Advanced diagnostic image quality enabled by high-contrast applications
- Zero-click postprocessingwith TwinBeam Dual Energy inline results
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 1/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Contrast media enhancement due to 70 kV imaging for all types of applications
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 2/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- High-resolution imaging with 1 mm MPRs thanks to Stellar detector and high numbers of projection
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 3/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Automated results
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 1/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- CARE kV combined with 10 kV Steps
- Automated, zero-click reconstruction of CPRs
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Stenosis evaluation of the coronaries Prospectively triggered sequential scan 2/2
SOMATOM go.Top
Scan time: 1 s / 6 s
Scan length: 147 mm
110 kV
CTDIvol: 10.3 mGy
DLP: 140 mGy cm
Heart rate: 61 bpm
- Optimal image quality due to CARE kV in 10 kV Steps
- Adaptive Cardio Sequence for dose-effective ECG-synchronized scanning
Evaluation of vascular territories Flex 4D Spiral scan
SOMATOM go.Top
Scan time: 41.8 s
Scan length: 58 mm 70 kV
CTDIvol: 145.8 mGy
DLP: 1604 mGy cm
- Flexible handling of 4D perfusion scans thanks to Flex 4D Spiral
- 70 kV for improved contrast to noise ratio
- Achieve a scan range of up to 8.4 cm with cycle time of 1.5 s
Trauma patient Native whole-body evaluation
SOMATOM go.Top
Scan time: 21 s
Scan length: 1875 mm 120 kV
CTDIvol: 6.08 mGy
DLP: 1175 mGy cm
- High resolution throughout the long scan range thanks to Stellar detector and powerful Athlon tube
- Automated result creation with Recon&GO
Evaluation of pancreatic mass Multi-phase including TwinBeam Dual Energy abdomen CT scan
SOMATOM go.Top
Scan time: 3 / 2 / 14 s
Scan length: 265 / 232 / 518 mm
110 / 130 / AuSn120 kV
CTDIvol: 6.7 / 7 / 6.1 mGy
DLP: 181 / 165 / 292 mGy cm
- Advanced diagnostic image quality enabled by high-contrast applications
- Zero-click postprocessingwith TwinBeam Dual Energy inline results
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 1/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Contrast media enhancement due to 70 kV imaging for all types of applications
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 2/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- High-resolution imaging with 1 mm MPRs thanks to Stellar detector and high numbers of projection
Metastatic spread evaluation during systemic therapy Single-phase contrast-enhanced CT scan 3/3
SOMATOM go.Top
Scan time: 16 s
Scan length: 654 mm 70 kV
CTDIvol: 6.37 mGy
DLP: 389 mGy cm
- Automated results
Technical details
SOMATOM go.Up
Slices | 64 |
z-Coverage | 32 x 0.7 mm |
Max. mA | 240 mA (400 mA8) |
Tube | 3.5 MHU |
Rotation time | Up to 0.5 s 1 |
Power | 32 kW |
kV | 80, 110, 130 kV |
Table load | 227 kg (opt. 307 kg) |
Bore size | 70 cm |
SOMATOM go.All
Slices | 64 |
z-Coverage | 32 x 0.7 mm |
Max mA | 625 mA (825 mA9) |
Tube | 7.0 MHU |
Rotation time | Up to 0.33 s1 |
Power | 75 kW |
kV | 70, 80, 90, 100, 110, 120, 130, 140 kV |
Table load | Up to 307 kg1 |
Bore size | 70 cm |
SOMATOM go.Top
Slices | 128 |
z-Coverage | 64 x 0.6 mm |
mA | 625 mA (825 mA9) |
Tube | 7.0 MHU |
Rotation time | Up to 0.33 s1 |
Power | 75 kW |
kV | 70, 80, 90, 100, 110, 120, 130, 140 kV |
Table load | Up to 307 kg1 |
Bore size | 70 cm |
Are you interested in buying a new CT scanner?
Please contact us for more details and prices for SOMATOM go. scanners.
Did this information help you?
Thank you.
High Power 80 available for SOMATOM go.Now and SOMATOM go.Up
Chronon® X-ray tube available for SOMATOM go.Now and SOMATOM go.Up
From generation to detection; Dr. Marcus Brehm; Published by Siemens Healthcare GmbH, 2021