MAGNETOM Amira with BioMatrix technology is our new 1.5T scanner that helps you differentiate your institution by delivering high-quality imaging even with complex variables – no matter what. Based on BioMatrix and the new syngo MR XA platform and equipped with our latest applications the system truly transforms the way you deliver care to your patients, enabling reproducible high-quality results you can count on – no matter what.
- Home
- Medical Imaging
- Magnetic Resonance Imaging
- 1.5T MRI Scanners
- MAGNETOM Amira - A BioMatrix System
![MAGNETOM Amira - A BioMatrix System](https://marketing.webassets.siemens-healthineers.com/b537ab66970c2ccf/7d21e92343ce/v/426b4d18bacd/siemens-healthineers_medical-imaging_magnetom-amira-a-biomatrix-system_hero-image.jpg)
MAGNETOM Amira - A BioMatrix System
No matter what
Features & Benefits
![MAGNETOM Altea](https://marketing.webassets.siemens-healthineers.com/64ffe4156b0ac5f5/32beddb1510b/v/5431040b24d3/MR_MAGNETOM_AMIRA_BioMatrix_Hot_Spot_Image.png)
![MAGNETOM Amira - A BioMatrix System - Consistent Quality](https://marketing.webassets.siemens-healthineers.com/1800000005912521/98809aa13cb7/v/f47717ba2efe/siemens-healthineers_mri_magnetom-amira-a-biomatrix-system_consistent-quality_1800000005912521.jpg)
![MAGNETOM Amira - A BioMatrix System - Consistent Quality](https://marketing.webassets.siemens-healthineers.com/1800000005912521/98809aa13cb7/v/f47717ba2efe/siemens-healthineers_mri_magnetom-amira-a-biomatrix-system_consistent-quality_1800000005912521.jpg)
Count on consistent quality with BioMatrix and DotGO
Each patient is unique. And patient variability and movement can make acquiring a diagnostic MR image difficult. Inconsistency among operators can further affect quality. Having to rescan patients after a failed scan not only impacts patient satisfaction, it also adds to your costs. With BioMatrix technology and DotGO, you can count on MAGNETOM Amira to give you reliably consistent quality by capturing respiratory motion, adapting to challenging body regions for excellent homogeneity, and decreasing acquisition time.
![MAGNETOM Amira - A BioMatrix System - Financial Certainty](https://marketing.webassets.siemens-healthineers.com/1800000005893863/5a22e6d08329/v/7a11048d3685/siemens-healthineers_medical-imaging_MAGNETOM-Amira_financial-certainty_1800000005893863.jpg)
Count on financial certainty productivity-boosting technologies
Finding a way to reconcile productivity improvements and cost savings while providing high-quality care is a major challenge in today’s healthcare industry. Overwhelming workloads and operating costs can drive down profits from your MR operations. MAGNETOM Amira with BioMatrix provides financial security by increasing patient throughput and delivering high-quality results with Simultaneous Multi-Slice and GO applications – also available with the new Turbo Suite packages. In addition, Eco-Power reduces energy consumption by up to 30%1 when the system is in stand-by mode.
![MAGNETOM Amira - A BioMatrix System - Clinical Opportunities](https://marketing.webassets.siemens-healthineers.com/1800000005893866/99768bac4b31/v/888cc1e49852/siemens-healthineers_medical-imaging_MAGNETOM-Amira_clinical-opportunities_1800000005893866.jpg)
Count on new clinical opportunities with free-breathing applications
To set yourself apart as a healthcare provider, you want to differentiate your institution through unique MRI services to attract more patients and referrers. MAGNETOM Amira with BioMatrix opens up new clinical capabilities that increase patient access to advanced MRI exams. Compressed Sensing provides a better patient experience by enabling free-breathing body and cardiac examinations – thereby transforming care delivery.
Customer Voices
Deep Resolve is a major change in MRI speed
Clinic Lyon Nord, France, is better able to meet patient needs through faster MRI scans with Deep Resolve. And they can scan up to 10 - 15% more patients than without Deep Resolve.
Clinical Use
![Respiratory triggered non-contrast MRA of renal arteries](https://marketing.webassets.siemens-healthineers.com/1800000006860367/a72ef96ba03d/v/77e5b641771e/folie_7_v2.jpg)
NATIVE with BioMatrix Respiratory Sensor
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![GOKnee3D](https://marketing.webassets.siemens-healthineers.com/1800000006860370/005be1f2b213/v/59731fefc283/folie_4_v2.jpg)
GOKnee3D
- UltraFlex Large 18
![Simultaneous Multi-Slice](https://marketing.webassets.siemens-healthineers.com/1800000006860418/33d8fcb68146/v/3c64a1f44d1f/folie_5_v4.jpg)
Simultaneous Multi-Slice
- iTX Extremity 18 Flare
![liver imaging](https://marketing.webassets.siemens-healthineers.com/1800000006860373/c0d8ed7c18ae/v/e250df39f100/folie_1_v2.jpg)
Compressed Sensing GRASP-VIBE
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![Respiratory triggered liver DWI](https://marketing.webassets.siemens-healthineers.com/1800000006860372/cec77b7c454d/v/7dfd77c00744/folie_2_v2.jpg)
BioMatrix Respiratory Sensor
b50, b400, b800 and ADC
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![TSE T2 fat sat BLADE acquired free-breathing](https://marketing.webassets.siemens-healthineers.com/1800000006860371/3cc2663af9f4/v/9627b9b4e107/folie_3_v2.jpg)
TSE T2 fat sat BLADE acquired free-breathing
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![Whole-Body](https://marketing.webassets.siemens-healthineers.com/1800000006860374/69a69f1262bb/v/e16c7a738c09/folie_8_v2.jpg)
Whole-Body
TA 00:18 per step
- Head/Neck 16
- 2x BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![Conventional vs. segmented time-of-flight](https://marketing.webassets.siemens-healthineers.com/f7ed24ee2e5cf7bf/0bf9da4a0c28/v/49dcaf2e0266/folie_6_v3.jpg)
Segmented time-of-flight
- Head/Neck 16
![Respiratory triggered non-contrast MRA of renal arteries](https://marketing.webassets.siemens-healthineers.com/1800000006860367/a72ef96ba03d/v/77e5b641771e/folie_7_v2.jpg)
NATIVE with BioMatrix Respiratory Sensor
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![GOKnee3D](https://marketing.webassets.siemens-healthineers.com/1800000006860370/005be1f2b213/v/59731fefc283/folie_4_v2.jpg)
GOKnee3D
- UltraFlex Large 18
![Simultaneous Multi-Slice](https://marketing.webassets.siemens-healthineers.com/1800000006860418/33d8fcb68146/v/3c64a1f44d1f/folie_5_v4.jpg)
Simultaneous Multi-Slice
- iTX Extremity 18 Flare
![liver imaging](https://marketing.webassets.siemens-healthineers.com/1800000006860373/c0d8ed7c18ae/v/e250df39f100/folie_1_v2.jpg)
Compressed Sensing GRASP-VIBE
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![Respiratory triggered liver DWI](https://marketing.webassets.siemens-healthineers.com/1800000006860372/cec77b7c454d/v/7dfd77c00744/folie_2_v2.jpg)
BioMatrix Respiratory Sensor
b50, b400, b800 and ADC
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![TSE T2 fat sat BLADE acquired free-breathing](https://marketing.webassets.siemens-healthineers.com/1800000006860371/3cc2663af9f4/v/9627b9b4e107/folie_3_v2.jpg)
TSE T2 fat sat BLADE acquired free-breathing
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![Whole-Body](https://marketing.webassets.siemens-healthineers.com/1800000006860374/69a69f1262bb/v/e16c7a738c09/folie_8_v2.jpg)
Whole-Body
TA 00:18 per step
- Head/Neck 16
- 2x BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![Conventional vs. segmented time-of-flight](https://marketing.webassets.siemens-healthineers.com/f7ed24ee2e5cf7bf/0bf9da4a0c28/v/49dcaf2e0266/folie_6_v3.jpg)
Segmented time-of-flight
- Head/Neck 16
![Respiratory triggered non-contrast MRA of renal arteries](https://marketing.webassets.siemens-healthineers.com/1800000006860367/a72ef96ba03d/v/77e5b641771e/folie_7_v2.jpg)
NATIVE with BioMatrix Respiratory Sensor
- BioMatrix Body 13 with Respiratory Sensor
- Spine 18
![GOKnee3D](https://marketing.webassets.siemens-healthineers.com/1800000006860370/005be1f2b213/v/59731fefc283/folie_4_v2.jpg)
![Simultaneous Multi-Slice](https://marketing.webassets.siemens-healthineers.com/1800000006860418/33d8fcb68146/v/3c64a1f44d1f/folie_5_v4.jpg)
![liver imaging](https://marketing.webassets.siemens-healthineers.com/1800000006860373/c0d8ed7c18ae/v/e250df39f100/folie_1_v2.jpg)
![Respiratory triggered liver DWI](https://marketing.webassets.siemens-healthineers.com/1800000006860372/cec77b7c454d/v/7dfd77c00744/folie_2_v2.jpg)
![TSE T2 fat sat BLADE acquired free-breathing](https://marketing.webassets.siemens-healthineers.com/1800000006860371/3cc2663af9f4/v/9627b9b4e107/folie_3_v2.jpg)
![Whole-Body](https://marketing.webassets.siemens-healthineers.com/1800000006860374/69a69f1262bb/v/e16c7a738c09/folie_8_v2.jpg)
![Conventional vs. segmented time-of-flight](https://marketing.webassets.siemens-healthineers.com/f7ed24ee2e5cf7bf/0bf9da4a0c28/v/49dcaf2e0266/folie_6_v3.jpg)
![Respiratory triggered non-contrast MRA of renal arteries](https://marketing.webassets.siemens-healthineers.com/1800000006860367/a72ef96ba03d/v/77e5b641771e/folie_7_v2.jpg)
Technical Details
Magnet System |
|
Field strength | 1.5 Tesla |
Bore size | 60 cm |
Magnet length | 155 cm |
Helium consumption | Zero Helium boil-off technology |
|
|
Gradient performance | |
Max. amplitude | 57 mT/m2 |
Max. slew rate | 217 T/m/s2 |
|
|
RF technology |
|
Maximum number of channels4 | 96 |
Number of independent receiver channels that can be | 16, 24 |
|
|
Power consumption | Eco-Power technology |
|
|
Siting and Installation |
|
System length from cover to cover5 | 168.5 cm |
System weight (in operation) | 4.56 tons |
Minimum room size6 | < 27.5 m2 |