Biograph™ mCT Sim edition features a large bore with access to intelligent imaging applications, making standardized protocols and personalized scans possible. Complex procedures, like PET motion-free imaging, can be transformed to an easy click of a button, and 4D CT workflow can be streamlined by automatically setting optimal scan parameters based on the patient’s breathing cycle. Biograph mCT Sim edition brings you a comprehensive solution for PET/CT in radiation therapy–driving the right planning for the right treatment.
- Siemens Healthineers Nederland
- Medical Imaging
- Molecular Imaging
- PET/CT Scanners
- Biograph mCT Sim edition
Biograph mCT Sim editionThe intelligent molecular RT simulator
Features & Benefits
Set the standard in PET/CT for RT
Biograph mCT Sim edition’s basic configuration sets the standard in PET/CT for RT planning. Offering technology that enables reproductivity across patients, personalization of scans, advanced motion management, and metal artifact reduction, Biograph mCT Sim delivers dedicated tools for a precise planning with dose optimization and time savings.
RT reproducibility
- RTP pallet
- TG-66 compliant patient table
- HD FoV Pro
- DirectDensity
- iMAR
Motion management
- PET/CT respiratory gating
- FAST 4D
- Phase-matched gating
- DirectBreathhold1
Intelligent imaging with AIDAN
Enabled by AIDAN, Biograph mCT Sim edition uses intelligent imaging applications to transform complex procedures and make standardized protocols and personalized scans possible.
Clinical decision making
Biograph mCT Sim edition offers an integrated workflow, enabled by syngo®.via, that supports clinical decisions along with a multimodality tool for deformable registration, dose visualization, beam placement, and more.
In addition to the Biograph mCT Sim edition, we have RT packages available for our Biograph Horizon and Biograph Vision™ scanners.
Technical Specifications
Gantry |
|
Bore diameter: | 78 cm |
Tunnel length: | 136 cm |
Table capacity: | 227 kg (500 lb) |
CT |
|
Generator power: | 80 kW, 100 kW* |
Rotation times: | 1.0, 0.5, 0.33, 0.30*, 0.28* s |
Tube voltages: | 70, 80, 100, 120, 140 kV |
Metal artifact reduction: | iMAR |
Optimized kV settings: | DirectDensity |
One-click 4D-CT: | FAST 4D2 |
Deep-inspiration breath hold acquisition: | DirectBreathhold* |
Iterative reconstruction: | SAFIRE* |
Slices: | 40, 64, 128 |
PET |
|
Axial field of view: | 16.4, 22.1* cm |
Crystal size: | 4 x 4 x 20 mm |
Time of flight performance: | 540 ps |
Respiratory gating: | Yes |