NAEOTOM Alpha.ProThe accelerator
The combination of photon-counting CT with the speed of
Dual Source CT in NAEOTOM® Alpha.Pro addresses the
challenges of sensitive patient groups.
• Thoracic examinations for patients who cannot hold their breath
• Cardiac exams in patients with severe calcifications or high heart rates
• Fast pediatric exams, at low doses, without compromising image quality
NAEOTOM Alpha.Pro is pending 510(k) clearance and is not yet commercially available in the United States and other regions.
Benefits
NAEOTOM Alpha.Pro accelerates diagnostic performance with conclusive images, helping physicians achieve fast diagnoses.
The ultra-high spatial resolution of NAEOTOM Alpha.Pro enables better diagnostic evaluation of coronary vessels than conventional CT with moderate radiation dose. The Dual Source temporal resolution provides unique insights into heart valves.
Photon-counting CT with Dual Source speed offers unique clinical capabilities for challenging patient groups. Scan cardiac patients without beta-blockers, pediatric patients without sedation, and perform free-breathing scanning for pulmonology patients.
The Dual Source speed of NAEOTOM Alpha.Pro enables short scan exposure times such that the thorax can be visualized without a breath hold. Quantum Spectral Imaging provides additional information in one single scan.
Quantum HD Cardiac at full temporal resolution of 66 ms allows accurate assessment of patients with severe coronary calcifications. This potentially shifts patient pathways to more conservative treatment options.
The NAEOTOM Alpha.Pro offers high-pitch scanning and spectral information at any scan speed, helping to ease the workflow and support diagnosis. Perfusion and iodine maps contribute to accurate diagnosis in oncology and stroke assessments.
myExam Companion delivers intelligent imaging with individuallyguided scans that optimize procedures to help leverage the full potential of the scanner. Automated AI-driven workflow solutions enable a faster operation and utilize zero-click Recon&GO to create the desired clinical outcomes.
Evidence
“Calcium is the enemy of interventional cardiologists and of CT imaging. And while many CT methods were previously not possible or aborted if a lot of calcium was present, we now have the possibility to precisely quantify the calcification.”¹
The NAEOTOM Alpha class in clinical routine
Technical Details
Product Specifications
Detectors
2 x 4 cm QuantaMax® photon-counting CT detector
X-ray tubes
2 x Vectron X-ray tube and Tin Filter
Max. number of acquired slices
2 x 96 slices
Number of physical detector rows
2 x 192 slices
mA
up to 1300 mA
Temporal resolution
down to 66 ms
kV
70, 90, 120, 140 kV
Sn100, Sn140, Sn150 kVz-coverage
96 x 0.4 mm
120 x 0.2 mm (Quantum HD)Spatial resolution
0.11 mm (in-plane) in Quantum HD mode
Power
2 x 120 kW
Table load
up to 750 lbs (340 kg)
Max. scan speed
491 mm/s (max pitch 3.2)
Related Products
Contact
The NAEOTOM Alpha class
Unstoppable
The statements by customers of Siemens Healthineers described herein are based on results that were achieved in the customer's unique setting. Since there is no "typical” hospital and many variables exist (e.g., hospital size, case mix, level of IT adoption) there can be no guarantee that other customers will achieve the same results.