This website uses cookies

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. We will only use cookies based on your decision.

BFT II AnalyzerHigh-performance analyzer for the low-volume lab

The BFT II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique turbodensitometric detection device. The semi-automated, dual-channel coagulometer is ideal for low-volume laboratories performing routine coagulation tests.

  • Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
  • Pre-defined assays with stored reference curves
  • Automatic calculation of PT in sec, % of norm, INR, Fibrinogen in mg/dL or g/L
  • Dual measuring channels allow for simultaneous determinations
  • Half-volume and single cuvette testing require minimal sample volume
  • Built-in thermal printer for consolidated result handling

Features & Benefits

The BFT II Analyzer is a dual-channel coagulometer designed for the lowest volume lab. It combines the advantages of mechanical and photo-optical clot detecting principles.

BFT II Analyzer - Features & Benefits

Total efficiency

  • Stores reference curves
  • Automatic result calculation, e.g., PT in sec, % of norm/ PR/ INR, Fibrinogen in mg/dL or g/L
  • Temperature controlled incubation block for reagents and samples
  • Sample mixing during measurement 

Ease-of-use

  • Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
  • Built-in timer for incubation
  • Membrane keypad for easy handling of test processing
  • Pre-programmed methods 

Labor and cost savings

  • Half-volume and single cuvette testing require minimal sample volume
  • Memory function for reference curves
  • As a back-up analyzer, the BFT II provides data comparable to those obtained with other Siemens hemostasis analyzers

Assays

PT Reagents
Dade® Innovin® INR
Dade Innovin sec
Dade Innovin %
Thromborel® S INR
Thromborel S sec
Thromborel S %

APTT Reagents
Dade Actin®
Dade Actin FS
Dade Actin FSL
Pathromtin® SL

Fibrinogen Reagents
Multifibren® U

Thrombin Time Reagents
Batroxobin Reagent*
Test Thrombin Reagent*
Thromboclotin®

Factor Deficient Reagents
Factor II-Dade Innovin*
Factor II-Thromborel S*
Factor V-Dade Innovin*
Factor V-Thromborel S*
Factor VII-Dade Innovin*
Factor VII-Thromborel S*
Factor VIII-Dade Actin*
Factor VIII-Pathromtin SL*
Factor IX-Dade Actin*
Factor IX-Pathromtin SL*
Factor X-Dade Innovin*
Factor X-Thromborel S*
Factor XI-Dade Actin*
Factor XI-Pathromtin SL*
Factor XII-Dade Actin*
Factor XII-Pathromtin SL*

Lupus Anticoagulant Reagents
LA 1 Screening Reagent*
LA 2 Confirmation Reagent*

Thrombosis Risk Reagents
ProC® Global*
ProC Global FV*
Protein C*

Technical Specifications

Dimensions

 

 

Approx. 200 mm x 300 mm x 100 mm (W x D x H)

Weight

 

 

Approx. 3.8 kg

Onboard Capacity

 

 

4 reagents including 1 reagent mixer

Incubation block for up to 30 cuvettes

Throughput

 

 

Approx. 60 PT tests/hour

Approx. 30 APTT tests/hour

Sample Handling

 

 

Manual sample pipetting

Reagent Handling

 

 

Manual reagent pipetting

4 positions GW 15 – bottles

GW5 bottles using reducer rings

Operation

 

 

Pre-programmed methods

2 free positions for user-defined methods

Built-in timer

Automatic timer start and stop

Subscription Button Icon
Be the first to know about our events, training, and news