MAGNETOM Sola1 Cardiovascular Edition automatically adjusts to patient biovariability to overcome unwarranted variations in cardiac MRI examinations. Connect with new capabilities. Gain speed, reliability and ease of use with BioMatrix Technology. Expand toward precision medicine by improving diagnostic accuracy and facilitating individual treatment strategies.
- Home
- Medical Imaging
- Magnetic Resonance Imaging
- 1.5T MRI Scanners
- MAGNETOM Sola Cardiovascular Edition
MAGNETOM Sola Cardiovascular EditionOutcome relevant decisions – redefining patient pathways
Caratteristiche e vantaggi
Free breathing exams
Get high-quality consistent cardiac MRI scans with Compressed Sensing Cardiac Cine for functional imaging even for patients with arrhythmias or dyspnea.
Tissue characterization
MyoMaps with HeartFreeze to detect myocardial injury and get patients on the right treatment pathway fast.
Consistent results, fast
BioMatrix Sensors and the AI-powered Cardiac Dot Engine provide fast patient setup and step-by-step guidance for standardized diagnostic cardiac MRI exams.
Uso clinico
Clinical Indications for Cardiac MRI
Indication:
Added value of CMR:
- Evaluation of orifice area
- Assessment of flow and hemodynamic relevance of structural disease
- Individual risk stratification
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Comprehensive assessment of significant CAD
- Diagnostic image quality in widest range of patients
- No ionizing radiation
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Identification of patients likely to benefti from coronary revascularization therapy
- Avoidance of invasive catheter procedure from patients with no/minimal chance to benefit
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Differentiation of myocardial tissue composition
- Identification of potential risk factors for sudden cardiac death (fibrosis in HCM)
- Identification of life threatening myocardial involvement in systemic disorders
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Quantification of tissue damage including differentiation of reversible and irreversible injury
- Differential diagnosis of inflammation to inform treatment strategy
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Evaluation of orifice area
- Assessment of flow and hemodynamic relevance of structural disease
- Individual risk stratification
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Comprehensive assessment of significant CAD
- Diagnostic image quality in widest range of patients
- No ionizing radiation
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Identification of patients likely to benefti from coronary revascularization therapy
- Avoidance of invasive catheter procedure from patients with no/minimal chance to benefit
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Differentiation of myocardial tissue composition
- Identification of potential risk factors for sudden cardiac death (fibrosis in HCM)
- Identification of life threatening myocardial involvement in systemic disorders
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Quantification of tissue damage including differentiation of reversible and irreversible injury
- Differential diagnosis of inflammation to inform treatment strategy
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Indication:
Added value of CMR:
- Evaluation of orifice area
- Assessment of flow and hemodynamic relevance of structural disease
- Individual risk stratification
Image courtesy of Charité Universitätsmedizin Berlin and Helios Clinics Berlin-Buch, Germany
Dettagli tecnici
Magnet System |
|
Field strength | 1.5 Tesla |
Bore size | 70 cm Open Bore design |
Helium consumption | Zero Helium boil-off technology |
|
|
Gradient strength | XQ gradients 45/200 simultaneously [2.03 MVA] |
|
|
RF technology |
|
Maximum number of channels2 | 204 |
Number of independent receiver channels that can be used simultaneously in one single scan and in one single FoV, each generating an independent partial image | 48 |
|
|
Power consumption | Eco-Power technology |
|
|
Siting and Installation |
|
System length | 157 cm cover to cover |
System weight (in operation) | 4.2 tons |
Minimum room size3 | 28 m2 / 302 sq ft |