See a whole new world of precision
Learn how Biograph Vision advances PET/CT beyond digital
LSO scintillator
For faster time of flight and better image quality
- Grown, cut, and individually selected in-house
- Self-manufactured to enable precise specifications and complete detector redesign
- Higher light output and faster scintillation,1 enabling faster time of flight and better image quality
3.2 mm crystals
Clinical images
Cardiology
01The ankle and knee joints are clearly delineated, and the bones of the mid foot can be visualized as well. Papillary musculature and excellent definition of the aortic wall and cardiac chambers can also be seen.
With Biograph Vision precise localization of PET activity can be achieved, which can possibly affect patient management.
High image quality with sharp definition of left ventricular margins with low noise on a 700 MBq (18.9 mCi) 82Rb for both stress and rest.
Excellent delineation of functioning cortex and sharp contrast between cortex and white matter. Additionally there is sharp basal ganglial edge definition, especially the sharp margins and distinct separation of the head of caudate nucleus and putamen.
The ankle and knee joints are clearly delineated, and the bones of the mid foot can be visualized as well. Papillary musculature and excellent definition of the aortic wall and cardiac chambers can also be seen.
With Biograph Vision precise localization of PET activity can be achieved, which can possibly affect patient management.
High image quality with sharp definition of left ventricular margins with low noise on a 700 MBq (18.9 mCi) 82Rb for both stress and rest.
Excellent delineation of functioning cortex and sharp contrast between cortex and white matter. Additionally there is sharp basal ganglial edge definition, especially the sharp margins and distinct separation of the head of caudate nucleus and putamen.
The ankle and knee joints are clearly delineated, and the bones of the mid foot can be visualized as well. Papillary musculature and excellent definition of the aortic wall and cardiac chambers can also be seen.
With Biograph Vision precise localization of PET activity can be achieved, which can possibly affect patient management.
SiPM technology
For optimized performance
- Provides 214 ps (picosecond) temporal resolution3 for the best-in-class time of flight and effective sensitivity
- 3.9x time of flight gain amplifies4 scanner sensitivity for faster scans and lower dose
Faster time of flight reduces noise
Increased detectability of small lesions.
Time of flight performance at 228 ps enables small segments of response.
Optiso UDR detector
What is UDR?
A small block detector with low dead time makes it suitable to operate in the high-activity concentrations found in studies with very short-lived tracers, such as 82Rb and 15O.
Did this information help you?
Thank you.
Biograph Vision and its features and applications are not commercially available in all countries. Their future availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details.
Compared to BGO crystals
Compared to competitive literature available at time of publication. Data on file.
Based on internal measurements at time of publication. Data on file.